5. AC Voltage detection: Place the detector
tip of the Voltage Detector near an AC
voltage. If the Voltage Detector detects
voltage within the defined detection
range, the green LED will turn off, the red
LED will turn on, and the beeper will beep
rapidly.
6. Low Battery Indication: Replace the
batteries if the green LED does not turn
on. When the Voltage Detector is on
and the batteries are too low for reliable
operation, the beeper will beep three
times and the green LED will turn off
indicating the Voltage Detector is not
operational. Replace the batteries to
restore operation.
7. Auto Power Off: To conserve battery life,
the Voltage Detector will automatically
turn off after approximately 5 minutes
of inactivity. When powering down, the
beeper will beep twice and the green LED
will turn off.
NOTE: If you press and hold the
button more 5 seconds, the Voltage
Detector regards this as error and it will
beep twice and then turn off.
CHANGING BATTERIES
1. Gently push down on locking tab.
2. While pushing down on tab,
slide cap off body.
3. Insert batteries positive ends first
4. Align locking tab with cap.
5. Slide cap onto Voltage Detector body.
OPERATION
1. Turning the Voltage Detector On:
Momentarily press the ON/OFF
button. The beeper will beep once and
the green LED will illuminate to indicate
that the Voltage Detector is on and ready
for use.
2. Turning the Voltage Detector Off:
Momentarily press the ON/OFF button.
The Voltage Detector will beep twice and
the green LED will turn off.
3. Turning the Beeper Off: Disable the
beeper by holding the ON/OFF
button down for more than two seconds
during power up. To enable the beeper
again, turn the Voltage Detector off and
then turn it on.
4. Verify Operation: Before using the
Voltage Detector, (1) Make sure the
green LED is glowing, (2) Check Voltage
Detector on a known live AC voltage that
is within the defined detection range of
the Voltage Detector.
OXFORD PRECISION
P.O. Box 14, Wigston, Leicester,
England, LE18 1AT.
THE ENVIRONMENT
DECLARATION OF CONFORMITY
We hereby certify that the OXFORD NON-CONTACT AC
VOLTAGE DETECTOR (ORDER CODE: OXD-516-1336M)
complies with all the relevant provisions of the
EMC Electromagnetic Compatibility Directive 2014/30/EU
Standards Applied: EN61326-1:2013, EN61326-2-1:2013,
IEC61326-1:2012, IEC61326-2-1:2012
LVD Low Voltage Directive 2014/35/EU
Standards Applied: EN61010-1:2010, EN61010-2-033:2012
RoHS2 Restriction of Hazardous Substances Directive 2011/65/EU
Position: Compliance Director
Date: September 2019
Always dispose of unwanted tools, accessories and packaging
materials in an environmentally friendly manner.
In observance of European Directive on Waste Electrical
and Electronic Equipment (WEEE) and its implementation
in accordance with national law, electrical goods that have
reached the end of their life must be collected separately and
returned to an environmentally compatible recycling facility.
Do not dispose of electrical goods with domestic waste
materials as inappropriate disposal may cause potential
hazards to the environment and human health.
For further information, please contact your local authority
or the retailer from whom you purchased the product.
QUALITY GUARANTEE & WARRANTY
OXFORD PRECISION products carry a one year manufacturer’s warranty.
OXFORD PRECISION products are designed & manufactured
to the highest standards & specifications.
Assuring the quality and performance required by all sectors of industry.
OXFORD PRECISION products are fully guaranteed
against faulty materials & workmanship.
Should they be found to be defective, they will either be repaired or
replaced free of charge (fair wear and tear and/or misuse excepted).
Please retain supplier invoice as proof of purchase.