4

SPECIFICATIONS

Insulation:  

Class2, Double insulation.

Over voltage category:  

CATII - 1000V.

Display:  

 2000 counts LCD display with function indication.

Polarity:  

 Automatic, (-) negative polarity indication.

Over range:  

“OL” mark indication.

Low battery indication:  

 “BAT” is displayed when the battery voltage drops 

below the operating level.

Measurement rate:  

2 times per second, nominal.

Operating environment:  

 0°C to 50 °C (32 °F to 122 °F) at < 70% relative 

humidity.

Storage temperature: 

 -20°C to 60°C (-4°F to 140°F) at < 80% relative 

humidity.

For inside use, max height: 

2000m

Pollution degree: 

2

Power: 

 One 9V battery , NEDA 1604, IEC 6F22.

Dimensions: 

195 (H) x92 (W) x 38 (D) mm

Weight: Approx.: 

380g.

Accuracy is given at  18°C to 28°C (65°F to 83°F), less than 70% RH

Input Impedance: 10MΩ.
200mV range Maximum Input: 250V DC or 250V AC rms.
Maximum Input: 1000V DC or 700V AC rms.

Input Impedance: 10MΩ.
Frequency Range: 50 to 400Hz 
Maximum Input: 1000V DC or 700V AC rms.

  5 

  6 

4.

V,

Ω

,CAP, Hz, TEMP. input jack

5.

mA input jack for mA DC or AC measurements

6.

20A (positive) input jack for 20A DC or

AC measurements.

7.

Data Hold pushbutton

8.

/

  pushbutton.

9.

Backlight pushbutton.

10. Power pushbutton: the power button turns the meter

ON or OFF.

SPECIFICATIONS

The instrument complies with: 

EN61010-1.

Insulation: 

Class2, Double insulation.

Overvoltage category: 

CATII - 1000V.

Display:

2000 counts LCD display with function indication.

Polarity:

Automatic, (-) negative polarity indication.

Overrange:

“OL” mark indication.

Low battery indication:

The  “BAT”  is  displayed  when  the 

battery voltage drops below the operating level.

Measurement rate: 

2 times per second, nominal.

Operating environment:

0 oC to 50 oC (32 oF to 122 oF) at

< 70 % relative humidity.

Storage temperature:

 -20 oC to 60 oC (-4 oF to 140 oF) at <

80 % relative humidity.

For inside use, max height: 

2000m

Pollution degree:

 2

Power:

One 9V battery , NEDA 1604, IEC 6F22. 

Dimensions:

195 (H) x92 (W) x 38 (D) mm

Weight: Approx.:

380g.

Accuracy is given at 18 oC to 28 oC (65 oF to 83 oF), less
than 70 % RH

DC Voltage

Range

Resolution

Accuracy

200.0mV

0.1mV

+0.5% of rdg + 2 dgts

2.000V

1mV

20.00V

10mV

200.0V

100mV

1000V

1V

+0.8% of rdg + 2 dgts

Input Impedance: 10M.
200mV range Maximum Input: 250V dc or 250V ac rms.
Maximum Input: 1000V dc or 700V ac rms.

AC Voltage

Range

Resolution

Accuracy

2.000V

1mV

+1.0% of rdg + 3 dgts

20.00V

10mV

200.0V

100mV

700V

1V

+1.2% of rdg + 5 dgts

Input Impedance: 10M.
Frequency Range:50 to 400Hz 
Maximum Input: 1000V dc or 700V ac rms.

DC Current

Range

Resolution

Accuracy

2.000mA

1µA

+1.0% of rdg + 3 dgts

20.00mA

10uA

+1.5% of rdg + 3 dgts

200.0mA

100µA

20.00A

10mA

+2.5% of rdg + 10 dgts

DC Voltage

  5 

  6 

4.

V,

Ω

,CAP, Hz, TEMP. input jack

5.

mA input jack for mA DC or AC measurements

6.

20A (positive) input jack for 20A DC or

AC measurements.

7.

Data Hold pushbutton

8.

/

  pushbutton.

9.

Backlight pushbutton.

10. Power pushbutton: the power button turns the meter

ON or OFF.

SPECIFICATIONS

The instrument complies with: 

EN61010-1.

Insulation: 

Class2, Double insulation.

Overvoltage category: 

CATII - 1000V.

Display:

2000 counts LCD display with function indication.

Polarity:

Automatic, (-) negative polarity indication.

Overrange:

“OL” mark indication.

Low battery indication:

The  “BAT”  is  displayed  when  the 

battery voltage drops below the operating level.

Measurement rate: 

2 times per second, nominal.

Operating environment:

0 oC to 50 oC (32 oF to 122 oF) at

< 70 % relative humidity.

Storage temperature:

 -20 oC to 60 oC (-4 oF to 140 oF) at <

80 % relative humidity.

For inside use, max height: 

2000m

Pollution degree:

 2

Power:

One 9V battery , NEDA 1604, IEC 6F22. 

Dimensions:

195 (H) x92 (W) x 38 (D) mm

Weight: Approx.:

380g.

Accuracy is given at 18 oC to 28 oC (65 oF to 83 oF), less
than 70 % RH

DC Voltage

Range

Resolution

Accuracy

200.0mV

0.1mV

+0.5% of rdg + 2 dgts

2.000V

1mV

20.00V

10mV

200.0V

100mV

1000V

1V

+0.8% of rdg + 2 dgts

Input Impedance: 10M.
200mV range Maximum Input: 250V dc or 250V ac rms.
Maximum Input: 1000V dc or 700V ac rms.

AC Voltage

Range

Resolution

Accuracy

2.000V

1mV

+1.0% of rdg + 3 dgts

20.00V

10mV

200.0V

100mV

700V

1V

+1.2% of rdg + 5 dgts

Input Impedance: 10M.
Frequency Range:50 to 400Hz 
Maximum Input: 1000V dc or 700V ac rms.

DC Current

Range

Resolution

Accuracy

2.000mA

1µA

+1.0% of rdg + 3 dgts

20.00mA

10uA

+1.5% of rdg + 3 dgts

200.0mA

100µA

20.00A

10mA

+2.5% of rdg + 10 dgts

AC Voltage

Summary of Contents for OXD-516-4320M

Page 1: ...well co uk Terminal blocking prevention Temperature measurement Extra large display Hold function Backlight Tilt stand Voltage DC 200mV 1000V Voltage AC 2V 700V Current DC 2mA 20A Current AC 2mA 20A R...

Page 2: ...6 F 9 200m 200 2 TEMP MAX 200mA FUSED mA 20 20 A F V C C 20 COM F V 2M 2 20m 2K 200 200 20K 200m V 1000 200 2 20 700 Hz 20K 20M HOLD 10 F 2 C 20 HOLD 200 X A M C F 4 3 2 8 1 7 Input Limits Function Ma...

Page 3: ...ndicates a potentially hazardous situation which if not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result...

Page 4: ...0 1mV 0 5 of rdg 2 dgts 2 000V 1mV 20 00V 10mV 200 0V 100mV 1000V 1V 0 8 of rdg 2 dgts Input Impedance 10M 200mV range Maximum Input 250V dc or 250V ac rms Maximum Input 1000V dc or 700V ac rms AC Vo...

Page 5: ...tection 250V dc or 250V ac rms Frequency Range Resolution Accuracy 20 00kHz 0 01Hz 1 5 of rdg 5 dgts Sensitivity 200mV 10V RMS Overload protection 250V dc or ac rms Temperature Range Resolution Accura...

Page 6: ...the Multimeter The indicators HOLD will appear in the display 2 Press the DATA HOLD button to return to normal operation BACK LIGHT BUTTON The BACK LIGHT BUTTON is used to turn the back light on only...

Page 7: ...ent measurements up to 20A DC set the function switch to the A position and insert the red test lead banana plug into the 20A jack 4 Remove power from the circuit under test then open up the circuit a...

Page 8: ...ately 50 an audible signal will sound The display will also show the actual resistance DIODE TEST WARNING To avoid electric shock do not test any diode that has voltage on it 1 Set the function switch...

Page 9: ...r making sure to observe the correct polarity 4 Switch the multimeter on and select C or F 5 Touch the temperature probe head to the part whose temperature you wish to measure Keep the probe touching...

Page 10: ...s using a Phillips head screwdriver 3 Insert the battery into battery holder observing the correct polarity 4 Put the battery cover back in place Secure the two screws WARNING To avoid electric shock...

Page 11: ...he back cover using a Phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse into the holder 5 Always use a fuse of the proper size and value 0...

Page 12: ...ical goods that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Do not dispose of electrical goods with domestic waste...

Reviews: