Cube С-02 turnstile
20
5.2. Connecting Control Panel
Remote control panel shall be connected to the Pult group of
contacts located on the cross-board. The contacts will have to be marked
as follows: 12V, CL, CH, GND.
Remote control panel connection shall be made on the basis of
contact marking, provided in Table 4.
Table 4.Contact marking for REMOTE CONTROL PANEL connection
Contact marking
Colour of wire
12V
Red
CL
Yellow
CH
Green
GND
Blue
5.3.Connecting ACS (optionally)
ACS Controller will have to be connected to the group of contacts:
Control located on the cross-board. The contacts will have to be
marked as follows: LEFT, RIGHT, STOP, AP, GND. Contact assignment
is indicated in Table 5.
Table 5. ACS contact assignment
Marking of contacts
Contact assignment
LEFT, RIGHT
One-pass movement to the left/to the right
(lowest priority)
STOP
No Entry (“Stop” mode)
(medium priority)
GND
Common contact