Cube С-02 turnstile
22
Fig.12. Motherboard of the turnstile
To change over to potential operation mode it is required to install
jumper X1 (Potential mode) on the motherboard in the position «ON»
(Fig.12). In this case the passage mode to the left/to the right is switched
on only for delivery time of the control signal to the inputs
LEFT/RIGHT. Free passage mode one can set by control signal supply
to both of the inputs simultaneously. The priority of the inputs LEFT
and RIGHT while changing over to a pulse mode will remain unchanged.
On the cross-board there are two relay outputs for AMCS, operating
under the principle of “dry contact” – Okl and Ok2. NO and COMM is
normally closed connection. Actuation of one of the contact group
testifies of a passage fulfilment to the appropriate side (Ok1–to the right,
Ok2–to the left). “Dry contact” is closed/opened when the arm turns
Summary of Contents for Cube C-02
Page 1: ...Installation guidelines www oxgard com info oxgard com Tel 7 812 366 15 94 Cube 02 turnstile...
Page 2: ......
Page 26: ...Cube 02 turnstile 26 Fig 15 Connecting diagram of control panel to ACS controller...
Page 29: ...Installation guidelines 29 Appendix 3 Diagram of the turnstile and its connection...
Page 30: ...Cube 02 turnstile 30...
Page 31: ...Installation guidelines 31...