Connection of RC panel to ACS controller is shown in Fig. 11. In this case
the controller controls the turnstile via "Left", "Right" and "Stop" contacts,
and the contact "antipanic" is turned on and off with the RC panel. Please
note that when the RC panel is connected via ACS controller it is
impossible to use turnstile modes which are set by the combination of the
RC panel buttons (except for the free passage in the potential control
mode. See section 5.3 of Manual). In this case ACS controls these
operation modes.