Installation guidelines
25
I / O1 ... I / O4 outputs can be connected either directly to the ACS
controller or via relay. When using the relay it is necessary (!) to connect
diode in parallel with the relay coil (Fig. 11).
Fig. 11 Connection of diode in parallel with relay coil
Connection of RC panel to ACS controller is shown in Fig. 12. In
this case the controller controls the speedgate via "Left", "Right" and
"Stop" contacts, and the "antipanic" contact is turned on and off with the
RC panel. Please note that when the RC panel is connected via ACS
controller it is impossible to use speedgate modes which are set by the
combination of the RC panel buttons (except for the free passage in the
potential control mode. See article 5.3 of Manual). In this case ACS
controls these operation modes.