Installation instructions
29
PROTECTING THE FUTURE
Table 4.
Labeling of the terminals for connecting the CB
Labeling of the
terminals
Color
of the wire
12V
Red
CL
Yellow
CH
Green
GND
Blue
5.2. Connection of the access control system (optionally)
The ACS controller is connected to the group of the terminals:
Access Control System at the cross-board. The terminals are marked
as: LEFT, RIGHT, STOP, AP, GND. The terminals are designated
according to Table 5.
Table 5.
Designation of ACS terminals
Labeling of the
terminals
Designation of terminals
LEFT, RIGHT
single-time passage to left/right
(the lowest priority)
STOP
the passage is forbidden (“Stop” mode)
(the middle priority)
AP
free exit (“Antipanic”)
(the highest priority)
GND
general terminal
The inputs for connecting the ACS are differed according to the
priorities: