Full-height turnstile Oxgard Praktika Т-10 (T-10H)
30
PROTECTING THE FUTURE
the highest priority is assigned to the output AP. While this input is
closed to the GND terminal, the turnstile is free for exit and NOT
RESPONDING (!!!) to other effects;
the middle priority is assigned to the output STOP. When closing this
input to the terminal GND, the turnstile is changing into the mode “Stop”
and is not responding to other effects besides AP;
LEFT and RIGHT are assigned with the same low priority and
designed to switch a single-time passage in one or opposite direction. If
the two inputs are closed, the passage is allowed in that direction whose
input was closed first. If the passage has not taken place, the turnstile
would be automatically switched into the mode “Stop” after 5 seconds.
CAUTION (!) If one of inputs STOP and/or AP is closed, the
commands from the board are not accepted as ACS is assigned with a
higher priority.
The inputs STOP and AP are potential ones, i.e. as long as the input
is closed to the terminal GND, the turnstile is operated in a respective
mode, whereas after opening the terminals the turnstile is switched into the
mode “Stop” irrespective of which mode was prior to ACS operation.
The inputs LEFT and RIGHT are operable both in a potential and
pulse mode as well (to be actuated in response to closing to the terminal
GND). The pulse mode is set as default.
In order to switch into a potential mode of operation it is necessary
to set the jumper J1 (Fig. 16). In this case the mode for passage to left/right
is switched only for the time of supplying a control signal to the inputs
LEFT/RIGHT. The mode of free passage can be set by simultaneously
Summary of Contents for Praktika T-10
Page 2: ...PROTECTING THE FUTURE...
Page 7: ...Installation instructions 7 PROTECTING THE FUTURE Fig 1 Initial position of the leaves...
Page 21: ...Installation instructions 21 PROTECTING THE FUTURE...
Page 26: ...Full height turnstile Oxgard Praktika 10 T 10H 26 PROTECTING THE FUTURE Fig 14 220 V 12 V...
Page 37: ...Installation instructions 37 PROTECTING THE FUTURE Fig 21 Sample for turnstile installation...
Page 39: ...Installation instructions 39 PROTECTING THE FUTURE...