Full-height turnstile Oxgard Praktika Т-10 (T-10H)
34
PROTECTING THE FUTURE
The diagram for connecting the CB to the ACD controller is shown
on Fig. 19. In this option the controller governs the turnstile by the
contacts “Left”, “Right” and “Stop”, while the contact “Antipanic” is
switched on/off by the board. An important feature for connecting the CB
via the ACS controller is that it is impossible to use turnstile modes which
are set by combinations of the board buttons (besides the mode of free
passage in a potential control mode, see the section 5.3 of the Instructions).
In this case ACS is responsible for these modes.
Fig. 19.
Diagram for connection of CB to the ACS controller
ACS
Cross-
board
Summary of Contents for Praktika T-10
Page 2: ...PROTECTING THE FUTURE...
Page 7: ...Installation instructions 7 PROTECTING THE FUTURE Fig 1 Initial position of the leaves...
Page 21: ...Installation instructions 21 PROTECTING THE FUTURE...
Page 26: ...Full height turnstile Oxgard Praktika 10 T 10H 26 PROTECTING THE FUTURE Fig 14 220 V 12 V...
Page 37: ...Installation instructions 37 PROTECTING THE FUTURE Fig 21 Sample for turnstile installation...
Page 39: ...Installation instructions 39 PROTECTING THE FUTURE...