User Instruction -
TM4BOX
V1.0 11/2021
6/16
EMERGENCY STOP:
Emergency STOP is the red button.
Emergency STOP button turns the controller to an inactive state and stays in it.
To release it, rotate the emergency stop clockwise.
When several more controllers are linked together, the press of any E-STOP button will shutdown
all connected controllers.
GO:
When active, the green pushbutton turns the selected channels of the Hoist Control system ON.
Once the GO button is released, the energizing of the hoists is turned off.
When several more controllers are linked together, the press of the first GO /MASTER/ in chain
will run all hoist controllers.
LINK:
For linking of several controllers, use a XLR 4 pin cable.
4. Operation guide
The motors/hoists connected to the TM4BOX controller can be activated individually or
simultaneously using the GO button located on the front panel, via cable remote or by linked
controller. The selection of the hoists that are controlled is made using the switches located on
the front panel.
Several TM4BOX controllers can be linked together to create bigger systems.
To start use connect the Power plug to the AC400V power supply and control MCBs.
• Connect the plugs of the electric hoists to the Harting socket or to the P17 socket.
• Check if all emergency STOP buttons, on device and on all other linked devices in the system
are released and there is the presence of security plug.
To Move a Single/Several Motor(s):
• Set the UP/DOWN switch for each motor to the desired direction.
• Hold the GO button until all motors are moved the desired height and release.