Oxford Technical Solutions Ltd. http://www.oxts.com
Page 17 of 42
Digital I/O
Table 9: Digital I/O electrical specifications
I/O
Typical
Min
Max
Input Low Voltage (V)
-
-20
0.5
Input High Voltage (V)
-
2
20
Output Voltage high (V)
3.3
2
3.3
Output Voltage Low (V)
0
-
0.8
Output Current (mA)
-
-
4
Note that triggers are pulled up internally to allow a switch to be used to short them to GND.
User cable
The standard xNAV650 user cable is designed for quick access to the main interfaces. Figure 7 shows
the cable diagram and Table 11 shows the pin descriptions for the interface connectors. At the end of
this manual there is a full page drawing of the user cable provided.
Power lines should be correctly terminated and insulated and wired up with a fuse somewhere between
the unit and power source before being connected to a power source. The user must again perform a
visual inspection of the cable equipment before use to ensure there is no damage.