background image

 

 

ARACHNE 230V – 24V- 12V

 

 

 

Arachne 230V, 24V

 

and 12V

 are brand names of 

Oxygen Automation Srl

  

All rights reserved 

 

 
 

 

 

GEARMOTOR FOR SWING GATES

 

 

      ARACHNE

 

12V-24V-220V

 

 

INSTRUCTIONS MANUAL 

 

 

 

We congratulate you on the excellent choice entrusted to us. Your new electro-mechanical gearmotor 
is manufactured in accordance with high quality and reliability; this will guarantee you performance and 
safety over time.  In this booklet you will find all the information you need to install your gearmotor and 
to protect your safety. 
 

CAUTION  IS  IN  ANY  CASE  IRREPLACEABLE  AND  THERE  IS  NO  BETTER  RULE  TO  PREVENT 
ACCIDENTS. 

 
All our products are manufactured in accordance with current regulations. 
 

This instruction booklet is intended exclusively for professional

 installers who are experts in the 

construction criteria and safety and accident protection devices for gates, doors, and motorized gates 
(comply with the regulations and laws in force). 

-  The installer must provide the appropriate explanations and issue the end user with an instruction 

manual in accordance with EN 12635. 

-  Before proceeding with the installation, the installer must carry out a risk analysis of the final 

automated closing and safety of the entire system (following EN 12453 and EN 12445 standards). 

-  The wiring of the various electrical components forming part of the automated closing system (e.g. 

photocells, flashing lights, etc.) must be carried out in accordance with EN 60204-1 and the 
modifications made by the latter in point 5.2.2 of EN 12453. 

-  Any repair or adjustment of the equipment is prohibited unless all precautions have been taken to 

avoid possible accidents (e.g. power supply disconnected, engine block). All moving parts must be 
fitted with appropriate guards. 

-  The power supply line must be protected for maximum current in blocked rotor condition. 
-  Install the gearmotor on gates in accordance with EN 12604. 
-  Have the force measurement developed by the operator carried out and take the measures 

provided for in EN 12445. 

-  Positioning of a possible pair of photocells: the radius of the photocells must be at a height not 

exceeding 70cm above the ground and at a distance from the plane of movement of the leaf not 
exceeding 20cm. Their correct functioning must be verified at the end of installation in accordance 
with point 7.2.1 of EN12445. 

-     All repair operations must be carried out by qualified personnel. 

Summary of Contents for ARACHNE

Page 1: ...installation the installer must carry out a risk analysis of the final automated closing and safety of the entire system following EN 12453 and EN 12445 standards The wiring of the various electrical...

Page 2: ...ation of the ecological platforms suitable to receive the product for disposal and its subsequent proper recycling Please also note that in exchange for the purchase of an equivalent appliance the dis...

Page 3: ...ged or cannot be removed take care of the following to their replacement been applied EN292 1 2 EN 294 EN60335 1 UNI EN 12453 as far as EN12445 2000 is applicable USE OF AUTOMATION The ARACHNE geared...

Page 4: ...ate weight 200Kg 200Kg 300Kg Power supply 12Vdc 24Vdc 220V Power 70W 70W 350W Capacitor 8 0 F Absorption 1 4 8 3A 1 4 5 3A 1 1A RPM 1500 1500 1400 Maximum thrust 260N 260N 320N Working temperature 25...

Page 5: ...gearmotor A B Alfa A B Alfa A B Alfa A B Alfa 0 cm 16 20cm 90 5 cm 25 35cm 110 15 cm 16 20cm 90 20 cm 16 35cm 90 0 cm 20 35cm 120 10 cm 16 20cm 90 15 cm 20 25cm 100 25 cm 16 30cm 90 5 cm 16 20cm 90 10...

Page 6: ...king it with the supplied A key until you hear the first click Fig 5 7 Using the articulated arm position bracket A on the gate so that the angle of the two elements of the articulated arm does not ex...

Page 7: ...ed 8 Make a complete movement of the sash by checking the correct arm movement 9 Check the fixings and proceed with the electrical connections adjust the A B cams of the limit switches as indicated in...

Page 8: ...que adjustment of the control unit Semiannual Electrician Check the torque setting as indicated in EN 12453 EN 12445 Protection degree control Semiannual Electrician Check that there are no traces of...