Rev.0 LEPTON
Service
manual
OXYGEN S.p.A.
18
BATTERIES ( LEAD SEALED VERSION )
Figure 6
MOUNTING / REMOVING THE BATTERIES
Four lead sealed batteries connected in series have been placed within the foot
board of the Lepton (1 - Figure 7). It’s important to know that each battery have an
OXYGEN data label.
NOTE:
there is an OXYGEN sticker with pertinent numbering information on each
battery. When the batteries are put back in, they must be placed in
numbered sequence.
Remove the case cover (2 - Figure 7) from the scooter to access the batteries. The
case cover is attached in the front with a lock (3 - Figure 7) and a notch in the back.
Press down on the front of the rod that holds the battery (4 - Figure 7), in place to
disconnect it from the fastening clamp (5 - Figure 7)
The batteries are placed in the designated space in a row according to the diagram.
Connect the batteries using the set of rapid contacts supplied. Verify that the pegs are
correctly attached to the terminals of the batteries. Remember that each contact must
be made between a negative and positive pole in the sequence listed.