background image

 

INSTALLATION MANUAL 
 

Our compliments for your excellent choice. The PERSEUS 230V electro-mechanical gear motor has been produced for reliability and high quality. This Manual 
will offer information you may need to install your gear motor assuring long-lasting performance and to safeguard your safety. 
HOWEVER CAUTION IS UNQUESTIONABLY INDISPENSABLE AND NOTHING IS BETTER THAN PREVENTING ACCIDENTS.  OXYGEN AUTOMATION  
products have been made to conform with rules and laws in force at time of manufacture. 

  This  manual  is  designed  exclusively  for  the  specialized  installation  of  experts  in  the  criteria  of  construction  and  equipment  to  assist  in  the  protection 

against accidents in the installation and use of the gate; door and automation of such gates (adhere to the rules and laws in force). 

 On completion the installer should issue to the end consumer an instruction manual according to EN 12635. 

  Before  proceeding  with  the  installation  the  installer  must  provide  an  analysis  on  the  identification  and  management  of  risks  as  per  the  standards  EN 

12453 and EN 12445. 

 All wiring of the various external electrical components connected  to the automation (e.g. Photocells, flashing lights, keypads etc) must be carried out 

according to EN 60204-1 and the amendments made of the point 5.2.2 of EN 12453. 

 It is prohibited to do any repair or adjustment of the equipment if you have not taken all necessary precautions to avoid possible accidents (example: 

power supply disconnected, engine block). All mechanisms in motion must be equipped with appropriate protections. 

 The mains power line must be protected for maximum current in locked rotor condition as per government  electrical laws. 

 Install the gear motor on gates that conform to EN 12604. 

 Perform the measure of strength developed by the gear motor and take the appropriate steps as per EN 12445. 

  Positioning  photocells:  These  safety  devices  must  be  installed  at  a  height  not  exceeding  70cm  from  the  ground  and  at  a  distance  from  the  floor 

movement of the door of no more than 20cm. Their proper functioning of the photocells must be verified at the end of installation according to Section 7.2.1 of 
EN12445. 

 Keep the activation controls of automation out of reach of children. The controls should be installed at a minimum 1.5m height above the ground and 

outside the range of actions of moving parts such as the gate. 

 All activation actions must be executed only at points from where the automation is fully visible. 

 Operate the remote only in view of automation. 

 Store carefully this manual in a suitable place known to all interested people. 

 Any  unauthorized  and  arbitrary  modification  made  to  this  product,  releases  the  company  OXYGEN  AUTOMATION  and  from  any  liability  resulting  from 
damage or injury to things, people or animals. 
The non-observance of regulations and of safety standards here listed releases the company OXYGEN AUTOMATION from any liability resulting from damage 
or injury to things, people or animals. 
The automation must be coupled to a control board equipped with torque regulation that provides an anti crushing safety as described in EN 12453 - EN 12445 
 
This  product  falls  within  the  scope  of  the  Directive  2012/19  /  EU  concerning  the  management  of  waste  electrical  and  electronic  equipment  (WEEE).  The 
appliance must not be disposed of with domestic waste as it is made of different materials that can be recycled at the appropriate facilities. Inquire through the 
municipal authority regarding the location of the ecological platforms to receive the product for disposal and its subsequent correct recycling. Furthermore, it 
should be remembered that, upon purchase of an equivalent appliance, the distributor is obliged to collect the product for disposal free of charge. The product 
is not potentially dangerous for human health and the environment, not containing harmful substances, but if abandoned in the environment negatively impacts 
on  the  ecosystem.  Read  the  instructions  carefully  before  using  the  appliance  for  the  first  time.  It  is  recommended  that  you  do  not  use  the  product  for  any 
purpose other than that for which it was intended, there being a danger of electric shock if used improperly. 
 

 

The  crossed-out  bin  symbol,  on  the  label  on  the  appliance,  indicates  the  compliance  of  this  product  with  the  regulations 
regarding waste electrical and electronic equipment. Abandonment in the environment of the equipment or illegal disposal of 
the equipment is punishable by law. 

 

 
DISMANTLING / REINSTALLING 
 

To dismantle or reinstall the automation elsewhere, you need to: 
1 - Disconnect the power supply and disconnect the electrical system. 
2 - Remove the control panel and all the components of the installation. In the event that some components are damaged or unable  to be removed, replace 
them. 

 
CONFORMITY DECLARATION: 

It’s in accordance with Machine Directive 39/89/CE and following modify. 
It’s in accordance with the following directive CE: 
Electromagnetic compatibility Directive 89/336/CEE and following modify. 
Low tension Directive 73/23/CEE and following modify. 
Have been applied the following harmonized norms: 
EN292/1/2, EN 294, EN60335-1, UNI EN 12453, and what applicable of the EN12445-2000. 
 

BOLOGNA 01/10/2020 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PERSEUS 230V

Page 1: ...PERSEUS 230V ...

Page 2: ... view of automation Store carefully this manual in a suitable place known to all interested people Any unauthorized and arbitrary modification made to this product releases the company OXYGEN AUTOMATION and from any liability resulting from damage or injury to things people or animals The non observance of regulations and of safety standards here listed releases the company OXYGEN AUTOMATION from ...

Page 3: ... adjustment of the electronic friction with which the electronic control board must be equipped PRELIMINARY CHECKS Read the instructions in the manual carefully Check that the gate is perfectly horizontal Check that it slides smoothly and without friction points Check that there is an adequate base for fixing the motor otherwise prepare it Check that the electrical system complies with the charact...

Page 4: ...ACK If the rack is already installed check that there is a space of approximately 1mm between the drive wheel and the rack FIG 4 if the rack is not installed proceed as follows Take the first piece of rack and position it on the motor sprocket making sure that at the end of the installation there is always 1mm of space if necessary use temporary shims under the motor Slide it to the point indicate...

Page 5: ... the rack to leave about 1mm of space between the motor sprocket and the rack Install the limit switch cams on the rack FIG 7 without fixing them in a definitive way in order to be able to adjust them in the optimal position when programming the control unit ATTENTION The limit switch cams are used to operate the limit switches of the motor which because of the control unit interrupt the movement ...

Page 6: ...Un errata installazione o un uso errato del prodotto può compromettere la sicurezza dell impianto Tutti i materiali presenti nell imballo non devono essere lasciati alla portata dei bambini in quanto fonti di pericolo WARNINGS The equipment must not be powered during wiring Installation and or maintenance must only be carried out by qualified personnel in compliance with the laws in force The manu...

Reviews: