18
8.1.
Connecting electric circuit
WARNING!!!
To prevent accidents and potential damage to the Unit, it can only be connected by a qualified
technician. Do not attempt to do that by yourself!
Mains supply power rating shall comply with the rating indicated in the Unit manual.
Mains supply should be disconnected when connecting the Unit.
The Unit should be connected according to diagram provided in the User Manual.
Only power cable provided with the Unit should be used to connect it to power source.
Grounding should be installed in compliance with the requirements of effective legislation and
standards when connecting the Unit to mains supply.
Electric circuit must be equipped with suitable power circuit-breaker.
Power supply
230V, 50Hz, 5A
Maximum electric power consumption – fans
167W
Maximum electric power consumption – preheater
2000W
Maximum electric power consumption – heater
2000W
IP protection class
20
8.2.
Installation of the control panel
It is recommended to install control panel of the Unit in a living space (for example, in a corridor or
hall) at 1.5 – 1.6 m height from the floor for convenient access. Lay the control panel connection cable
supplied from the Unit location to the control panel location before finishing decoration works.
The maximum permissible installation distance of control panel from the Unit is 100 m. Use a flexible
mounting cable 4x0.22mm² to connect the panel, the resistance of each conductor must not exceed
40
ꭥ
.
IT IS PROHIBITED
to install control panel in premises, where relative air humidity exceeds 70%.