OPERATING AND MAINTENANCE INSTRUCTIONS 

 

 
4. First use 

 

4.1 Preliminary remark 

 
The unit was thoroughly checked and carefully packed before leaving the factory. 
 
If the packaging is damaged or opened, check the unit for external damage  
immediately upon receipt. 
 
Never put a damaged unit into operation. In the event of a complaint, contact 
your supplier immediately. 
 
Observe the technical data as well as the safety instructions before the first 
operation. 
 
 

4.2 Scope of delivery 

 
1 x Device  
1 x Mounting plate 
1 x Remote control 
1 x Operating instructions 
 
 

4.3 Assembly 

 
1.

 

The mounting plate is fixed to the ceiling with 

four screws. Select the dowels according to the 
ceiling material and the dowel manufacturer's 
specifications. Please pay attention to the 
discharge direction of the unit. 
 

2.

 

Remove the protective strips  from the two outlet grilles. 

 
3.

 

Connect the power cable to the connection cable on the unit. 

 
4.

 

Hang the unit in the mounting plate and secure it with the locking screws. 

Summary of Contents for CLEANAIR SKY

Page 1: ...OPERATING AND MAINTENANCE INSTRUCTIONS CLEANAIR SKY NT PLASMA UNIT WITH VOLUME PLASMA FOR ROOM AIR DISINFECTION AND ODOUR ELIMINATION ...

Page 2: ...6 1 3 Foreseeable misuse 6 1 4 General safety instructions 6 2 Technical Data 8 3 The Cleanair Sky 9 3 1 Pre filter stage 10 3 2 Fan 10 3 3 NTP Electrode 10 3 4 Product filter 10 3 5 Activated carbon catalyst 10 3 6 Remote control 11 3 7 Time programs 11 4 First use 12 4 1 Preliminary remark 12 4 2 Scope of delivery 12 4 3 Assembly 12 ...

Page 3: ...4 Power level 14 5 5 Switch off the unit 15 5 6 Display 15 6 Maintenance and Care 16 6 1 Cleaning 16 6 2 Change pre filter 16 6 3 Change activated carbon filter 16 6 4 Maintenance intervals 17 6 5 Malfunction 17 6 6 Spare parts 18 7 General information 19 7 1 Transport 19 7 2 Disposal 19 7 3 Guarantee 19 7 4 Certificates 20 7 5 Service 22 ...

Page 4: ... viruses bacteria and germs are destroyed The air is sterilised in fractions of a second Unlike all other plasma processes on the market the Cleanair does not only disinfect the air with activated oxygen In the NT plasma process the air travels through the volume plasma and is disinfected by oxidation The Fraunhofer study has proven that this does not result in any critical contamination of the ro...

Page 5: ...5 OPERATING AND MAINTENANCE INSTRUCTIONS 1 Safety instructions 1 1 Safety and warning labelling All Warning of dangerous electrical voltage Motor High voltage transformer Rotating parts Fan Motor ...

Page 6: ...e the appliance without supervision or instruction by a responsible person Maintenance of the unit only by instructed personnel 1 3 Foreseeable misuse Any use other than that specified under the intended use shall be deemed to be improper use oxytec accepts no liability for consequences arising from improper use The guarantee does not apply to damage or defects caused by non compliance with the op...

Page 7: ...d Only connect the unit to a mains voltage according to the type plate Never repair the unit yourself Do not make any modifications to the unit The unit contains live parts There is a danger to life if the housing is opened Only use original accessories When carrying out cleaning and maintenance work always switch off the fuse and secure it against being switched on again ...

Page 8: ...on Cable length 80cm Fan Level 1 4 selectable Fan speed 1 150 m h 30dB 21 Watt Fan speed 2 265 m h 39dB 26 Watt Fan speed 3 410 m h 49dB 39 Watt Fan speed 4 600 m h 58dB 75 Watt Filter Pre filter G4 NTP Electrode Product filter F9 Activated carbon catalyst Net weight 13 kg Dimensions 210 x 680 x 610 mm H x W x D Ambient temperature Temperature range 10 C 30 C ...

Page 9: ...erosols as well as dust These can become become a source of infection in times of pandemic The Cleanair inactivates viruses bacteria and spores highly effectively The air currents in the room are taken into account The unit which is suspended centrally under the ceiling ensures an even optimal air exchange Air intake Discharge direction Discharge direction ...

Page 10: ...ote control 3 3 NTP Electrode The proprietary NTP electrode has been developed for air treatment The volume plasma it generates is capable of destroying or inactivating organic compounds such as odours or microorganisms in fractions of a second It has a minimal energy consumption 3 4 Product filter The reaction in the volume plasma can lead to cluster formation These dust particles are then filter...

Page 11: ...me programs These levels can also be adjusted via the remote control Power level In this level the unit operates with a volume flow of 600 m h Because of the slightly higher volume this level can be used during break times Its running time is set to 10 minutes After that the unit returns to the previous stage Run on When the unit is switched off it can run on for 30 minutes ...

Page 12: ...s well as the safety instructions before the first operation 4 2 Scope of delivery 1 x Device 1 x Mounting plate 1 x Remote control 1 x Operating instructions 4 3 Assembly 1 The mounting plate is fixed to the ceiling with four screws Select the dowels according to the ceiling material and the dowel manufacturer s specifications Please pay attention to the discharge direction of the unit 2 Remove t...

Page 13: ...13 OPERATING AND MAINTENANCE INSTRUCTIONS ...

Page 14: ...he stage in which it was switched off Or Plus Button Unit starts with level 1 5 3 Select fan level Select the appropriate level 1 4 with the plus or minus key 5 4 Power level Press the pause button The unit goes to level 4 for 10 minutes and then switches back to the output level Plus Button Restore Button Minus Button Pause Button Menu Button ...

Page 15: ...y pressing the button again Or Restore Button Unit switches off but saves the level for the next time it is switched on Or switch off voltage The next time the unit is switched on again to the same level as before it was switched off 5 6 Display Level 0 Unit is off but on voltage Level 1 3 Normal running levels Level 4 Power Level Next to the display is the infrared receiver to which the remote co...

Page 16: ...nge the filter when it is switched off To change the prefilter open the inspection flap and pull out the filter cassette Then install the new filter and close the flap 6 3 Change activated carbon filter To change the filter loosen the screws on the sides of the outlet nozzles and remove the nozzles with the filter Replace the filter Reinstall the outlet connection pieces and tighten them with the ...

Page 17: ...ls Pre filter You should change the filter every 3 to 6 months by pulling out the filter cartridge Product filter and activated carbon catalyst after 9000 operating hours Product filter and activated carbon catalyst after 9000 operating hours With eight hours of operation per day this corresponds to five years The unit indicates when it needs to be changed 6 5 Malfunction Unit cannot be switched o...

Page 18: ...ns in mm Filterset Sky Replacement filter set consisting of Prefilter G4 Product filter F9 2 Activated carbon catalysts 4 Prefilter Sky Prefilter G4 392 x 495 x 24 L x W x H Product filter F9 F9 Filters 2 595 x 130 x 25 L x W x H Carb Sky Activated carbon catalysts 4 595 x 130 x 25 L x W x H ...

Page 19: ...as a consumer you are obliged to return electrical and electronic equipment at the end of its service life free of charge to the manufacturer the point of sale or to public collection points 7 3 Guarantee We guarantee to repair any defects in the material and function of your device free of charge for two years for private customers or one year for companies and business customers Your invoice is ...

Page 20: ...r rer nat Andrea Burdack Freitag Bearbeiter M Sc Sabine Johann Fraunhofer Institut für Bauphysik IBP Nobelstraße 12 70569 Stuttgart Telefon 49 711 970 00 Telefax 49 711 970 3395 www ibp fraunhofer de Fraunhoferstr 10 83626 Valley Telefon 49 8024 643 0 Telefax 49 8024 643 366 IBP Bericht Nr UHS 054 2021 Effizienz des Raumluftreinigers von oxytec Cleanair Sky L auf die Reduktion und Inaktivierung vo...

Page 21: ...dy measurable after 45 minutes In comparable studies often only salt water is evaporated in the room or viruses are only tested in a test tube or on a filter Inside the Cleanair Sky the air flowing through it is put into a non thermal plasma state for an extremely short time and the viruses are inactivated Ozone is formed in the process This reaction only takes place inside the unit Therefore the ...

Page 22: ...IONS 7 5 Service If you have any questions about your Cleanair Sky please feel free to contact us You can reach our customer service at oxytec ag Bahnhofstraße 37 CH 8001 Zürich P 41 0 44 214 62 94 F 41 0 44 214 65 19 oxytec oxytec ag com ...

Page 23: ... 49 40 480 967 72 Phone 00 41 44 214 6294 Fax 00 41 44 214 6519 INFORMATION Internet www oxytec com Email order oxytec com Internet www oxytec ag com Email order oxytec com oxytec ag Bahnhofstraße 37 CH 8001 Zürich oxytec oxytec ag com Company s head office Zürich HR CH 020 3 027 944 9 EORI Number DE1182145 UST ID DE 81 41 24 612 UID CHE 111 788 373 EU Store Raiffeisenstraße 21 D 59757 Arnsberg ...

Reviews: