background image

7 • Oz Charge manual   

www.ozcharge.com.au

TROUBLE SHOOTING

Problem

Indication

Possible Causes

Suggested Solution

Charger does 

not work.

No Indicator 

lights are not 

on

- No AC power

- Unit not connected to 

battery

- Blown AC fuse (Internal)

- Check AC connection and

make sure Power Point and

Charger are switched ON

- Check Battery is connected

to Charger properly.

- Contact Supplier for Service.

(No user serviceable parts

inside)

Charger has 

no DC output.

Fault LED is

Flashing.

-Output is short circuited

- Output cables are not

connected to the battery.

- Output Reverse polarity

connection

- Battery Weak / Damaged

- Charger has overheated

Check that there are no foreign

objects inside the XLR

connectors.

- Check that the XLR plugs have

been securely connected.

- Check that the XLR plugs have

not been forced together

incorrectly.

- Move charger to a cooler area.

- Refer to LED Indicator Table.

No charging 

current.

Fault LED is ON

Battery is severely sulphated

- Battery has a damaged cell

- Check the Battery condition,

age etc.

- Battery may need 

replacement

Long charging

time, Full light

does not

come on

Fault LED is

Flashing

- Battery capacity too large

- Battery is defective

- 6 hours Soft Start timed out

- 24 hours Bulk Charge 

timed out

- Check the charger 

specification

matches the battery capacity.

- Battery cannot be charged

and must be replaced.

REPLACEMENT PARTS

For the full range of replacement parts and accessories, please visit our website:
www.ozcharge.com.au. / www.ozcharge.co.nz

Summary of Contents for OC2404M

Page 1: ...OWNER S MANUAL Model OC2404M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Page 2: ......

Page 3: ...unning cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead acid batteries remove personal metal items such as rings bracelets necklaces watches and make sure you don...

Page 4: ...batteryrejuvenationtechnology The charger has a unique and patented rejuvenation feature which uses high voltage equalising and peak pulse reconditioning to repair sulphated batteries This feature is fully automatic and depends on the internal impedance of the battery and battery voltage Canbelefton24 7toensureyourbatteryisalwaysmaintainedandfully charged The battery charger can be left unattended...

Page 5: ...y SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthecharger frombeingdamagedifthepositiveandnegativecrocodileclipsorringterminals accidentlytoucheachotherwhilethechargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power consumption circuit If AC power is connected and t...

Page 6: ...re 25 to 85 C Operating Humidity 90 RH Max Size L W H 214mm x 103mm x 55mm Weight 1 1kg Approvals CE UL cUL AS NZS EMC CHARGING INSTRUCTIONS STEP 1 Pre charge check electrolyte level check Check the Battery Electrolyte levels Not required on sealed maintenance free batteries If necessary remove the vent caps and add distilled water so the levels are halfway between the upper and lower fill lines C...

Page 7: ...OFF Disconnect the battery charger from the battery charger socket Note Thechargerhasbeendesignedtobeleftturnedonandswitchingthechargeron offtoconnect reconnectisnotnecessary LED STATUS INDICATOR TABLE LED Status Description ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or...

Page 8: ...attery voltage doesn t reach 22V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Uses the maximum charge output until the battery voltage reaches 28 8 If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the R...

Page 9: ...ated Checkthattherearenoforeign objectsinsidetheXLR connectors CheckthattheXLRplugshave beensecurelyconnected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverelysulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot come...

Page 10: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Page 11: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Page 12: ...OC2404M Owner s Manual Rev 1 0 5 15 Specifications subject to change without notice SAAApproval No GMA 102826 EA 002 ...

Reviews: