6 • Oz Charge manual 

 www.ozcharge.com.au

STEP 3 - Disconnecting the battery charger from battery

• 

Switch the battery charger OFF then switch the mains power OFF.

• 

Disconnect the battery charger from the battery charge socket.

Note: The charger has been designed to be left turned on and switching the charger on-

off to connect/reconnect is not necessary.

LED STATUS INDICATOR TABLE:

Orange Green Red

Description

OFF

OFF

OFF

AC Power OFF/ Switch is OFF/ Battery Disconnected

ON

OFF

OFF

Charging / Battery Connected

OFF

ON

OFF

Fully Charged (Float/Trickle maintenance charging)

OFF

OFF

FLASH (1)

Output lead short/ reverse polarity

OFF

OFF

FLASH (2)

Soft Start Charge Timed Out

OFF

OFF

FLASH (3)

Bulk Charge Timed Out

OFF

OFF

FLASH (4)

Overheat Protection Mode

OFF

OFF

ON

Weak/ Faulty Battery. Poor initial current acceptance

CHARGING CURVE

SOFT START

BULK CHARGE

ABSORPTION

FLOAT

Increases your battery 

life by gently starting to 

charge the battery until 

the battery reaches

a set voltage.

Reduces charging time 

by delivering maximum 

charge until the battery 

reaches a set voltage.

Uses constant voltage 

and ensures the battery 

receives a full charge 

without overcharging the 

battery.

Maintains the battery 

at 100% charge.

1

2

Summary of Contents for PX2408M

Page 1: ...OWNER S MANUAL Model PX2408M AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Page 2: ......

Page 3: ...n or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger When working with lead...

Page 4: ...e your battery is always maintained and fully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance Short circuit and reverse polarity protection The PX2408M will recharge the battery set to 80 of the rated capacity in a period not exceeding 8 hours IP51 rate...

Page 5: ...top charging in order to protect the battery This will be indicated with the fault LED flashing REVERSE POLARITY The charger has reverse polarity protection If the charger output leads are connected reverse polarity the fault LED will come on and the charger will be disabled SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED wil...

Page 6: ...40Vac 1 6A Input Frequency 50 60Hz ChargeVoltage 29 0V FloatVoltage 27 4V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 185mm x 153mm x 70mm Weight 1 7kg Approvals CE AS NZS EMC CONTROL AND INDICATORS 1 Charging status Display LED Fault RED refer to LED STATUS indicatorTABLE on page 6 Charging Process Orange Fully Charged Gree...

Page 7: ...each 23V within 4 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashing 2 Bulk Charging Orange Charging LED ON Uses the maximum charge output 8A until the battery voltage reaches 29 0V If the battery voltage doesn t reach 29 0V within 16 hours the safety timer protection will stop the unit from charging and the Red Fault LED will start flashin...

Page 8: ... ON OFF Fully Charged Float Trickle maintenance charging OFF OFF FLASH 1 Output lead short reverse polarity OFF OFF FLASH 2 Soft Start ChargeTimed Out OFF OFF FLASH 3 Bulk ChargeTimed Out OFF OFF FLASH 4 Overheat Protection Mode OFF OFF ON Weak Faulty Battery Poor initial current acceptance CHARGING CURVE SOFT START BULK CHARGE ABSORPTION FLOAT Increases your battery life by gently starting to cha...

Page 9: ...eckthatthereareno foreignobjectsinsidethe3 PinXLRconnectors Checkthatthe3PinXLRplugs havebeensecurely connected CheckthattheXLRplugshave notbeenforcedtogether incorrectly Movechargertoacoolerarea RefertoLEDIndicatorTable Nocharging current FaultLEDisON Batteryisseverely sulphated Batteryhasadamagedcell ChecktheBatterycondition ageetc Batterymayneed replacement Longcharging time Fulllight doesnot c...

Page 10: ... a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Page 11: ......

Page 12: ...PX2408M Owner s Manual Rev 1 2 12 14 Specifications subject to change without notice SAAApproval No 111981EA 001 ...