WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS STOVE.
LOCATION AND SAFETY DISTANCES
4.19.
Check the space between the stove, the fuel, and any flammable material, check
drawing 3
.
4.20.
Do not install the stove in a sleeping room.
4.21.
The power cable provided by
OZ Energia
is 1.4m long; you might need a longer one.
Always
use a cable with
ground plug.
FREE SPACES AND MINIMUM DISTANCES WITH FLAMMABLE MATERIAL
Security distances should be respected when the stove is installed in spaces where materials, either
construction materials or those surrounding the stove, are likely to be flammable.
4.22.
If the floor is made of a combustible material, install a fire protection between the floor and the stove.
Drawing 3
EXAMPLES OF FLUE INSTALLATIONS
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, OZEnergia
guarantees that the installations suggested below will enable
your stove to function properly, and to conform to minimum personal and material safety measures.
If you are installing your stove in a building, in addition to respect local regulations on gas flues, you should
consult with the residents’ association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your stove
operates properly and at full power.
4.23.
The installation shown below is the most common. Please bear in mind that if the gas flue pipe located on
the outside of the dwelling is in an area where people pass by, insulated tube must be used.
A
Lateral wall
≥
E
B
Back of the stove. Minimum separation
that allows visualizing the label
marking the stove
≥
80 mm
C
1.5 x depth of stove
See dimensions
D
Shelf
≥ 500 mm
E
Depth of stove
See dimensions
24