59
© Oz inventions
Version 1.8
Trouble shooting
Problem
Resolution
The display and modulation does not change
Check minimum depth control
Check maximum depth control
Check sensitivity control
The display and modulation are slow to change in tilt
mode
Increase sensitivity control
Modulation is too sensitive
Reduce sensitivity control
Nothing is playing back after a recording
Reduce sensitivity control (trim)
The display only changes a little in flick or velocity modes
Increase sensitivity control
The channel indicator is not lit
Match channel to sensor-transmitter channel
Modulation is not smooth or jumps large steps
Check polarity setting and/or resistance settings
Display is functioning smoothly but there is no modulation
effect
Turn modulation on
Check polarity and/or resistance settings
Check setup of device being modulated
Modulation jumps in steps
Normal operation. Check ‘step size’ setting and/or
linear/logarithmic settings
Recording is armed but does not begin
Record trigger level set too high
The angle over which modulation occurs is too large or
too small
Re-calibrate
No lights and no display
Check power adapter configuration
Channel indicator blinks
Poor reception
Attach antenna
Stay within range of sensor-transmitter
Antenna is not vertical
Calibration is not working
Check that ‘free’ or ‘AtrG’ mode is selected in menu
Modulation is not triggering the ADSR envelope on and/or
not triggering it off
Ensure that maximum depth is being reached to trigger
the envelope
Rotation mode not working when moved up and down
Normal operation. Rotation mode only works on a
horizontal plane
Automatic ADSR modulation is not smooth
Check ADSR settings. Settings less than 5 for attack and
decay rates simultaneously whilst the scale is less than 2,
are not supported
Menu cannot be accessed or exited
Ensure the correct order of switch and controls is used (pg
21)
Not working properly after menu exited
Check minimum depth control
Check maximum depth control
Check sensitivity control
Not working properly after modulation mode changed
Check minimum depth control
Check maximum depth control
Check sensitivity control
Modulation keeps turning on and off
Check ‘Soft power on/off’ as it may be set to low and
thereby causing modulation to turn on/off as tilting etc is
occurring.
Many menu item values have changed accidently
Be careful not to move the maximum depth control when
moving through the menu items with the minimum depth
control
The automatic arpeggiator timing is off
Adjust the maximum and/or minimum depth controls as
required
The controls skip a number
Turn the control slowly or turn the control to maximum
and try again
Everything has been tried, but it won’t work, or it seems
stuck
Turn power off and on
Load default settings (system reset)
Contact Oz Inventions