10
4.1 Power and Grounding Connections
4.2 Control Board Connections
4. SETUP AND OPERATION
WARNİNG / DİKKAT
220 V. 50 Hz.
FUSE
ERT
F
N
Warning! Power and grounding connections
must be made by a qualified electrician in
accordance with the relevant local regulations
using appropriate materials!
Proper grounding must be ensured to prevent
shock hazard!
Warning! Never remove the protective cover of the power supply
unit for any reason!
In case of a power supply failure, the power supply unit must be
replaced with an original unit obtained from Ozak.
Cable Routing
Area
M8 Washer
M8 Lock Washer
M8 Nut
M8x120 Anchor
Turnstile Base Plate
Ground
1,5 mt (CAT 5, CAT 6 etc.)
Data Cable above surface
1,5 mt 3 x 1,5 TTR
Power Cable above surface
Ø197
120°
120°
Ø166,6
3
Mounting Holes
Cable Routing
Area
Note:
For optimal flow rate contact duration of 1 second or less is recomended.
SN
Access Control Terminal
Res
+24V
B-A
B-A or A-B
A-B
N.O.
N.O.
Com
Com
Gnd
Gnd
Emg
INB
Gnd
Gnd
Gnd
Gnd
INA
1
2
3
7
5
6
8
-
Po
wer
+
B-A
A-B
J3
Top Indicators
Side Indicators
Motor Control
Direc
tion Sensor
s
ON
DipSwitch
1 2 3 4
U2
U7
U1
RL1
RL2
U9
A
B
Prg: XXXXXXXXXXX
Rx
Tx
I/O_
1
I/O_
2
I/O_
3
I/O_
4
Out_P3
Out_P2
Out_P1
+5
V
+24
V
Gnd
0.5 - 1 sn
dry contact
or open collector input
88888
8
Optional counter
1N4001 or similar
Busy Out
or
or
TRN1202
0.5 - 1 sn
busy
B-A
A-B
Enable
Gnd
Passage confirmation dry contact output
Use with access control systems, counters etc.
accessories (0.5 sec. N.O. contact)
Buzzer Jumper
(Buzzer disabled when removed.)
Connect a jumper from Enable A-B or B-A to Gnd to block
a passage direction.
Res: Manual Time Reset (Optional)
24 VDC
Optional counter
sample connection
During Passege = 0
Emg: Emergency-Free Access Mode
(when contact is open.)
Gnd
Enable
TURNSTİLE POWER WARNING LABEL
Ground (GND)