DD-75-193 R(0)
Y.T
.31.03.17
12
9
1.
Turnstile is factory preset (see dip switch settings) for bi-directional controlled access. For one way access, or single button/ reader
operation please refer to
4.4 Control Board Settings
2.
After completing the installation steps, gently bring the panel to the center position and apply power . Buzzer is heard, RGB indicator on
top flashes white for a few seconds and then buzzer stops, RGB indicator turns blue indicating that the turnstile is in standby mode.
3.
When a momentary contact is given into ’INA’ terminal, top indicator flashes green, buzzer is heard and panel opens by turning 90
degrees in clockwise direction. Panel remains open for 6 seconds (default setting) and then returns to center. For opening in the
opposite direction a contact is required on ‘INB’ terminal.
4.
Panel remains open when continuous contact is present on INA or INB.
5.
If a continuous contact is given on Emg. terminal, buzzer is heard, indicator flashes green, panel opens in clockwise and remains open for
duration of the contact. This feature can be used with fire alarm system to open the gate automatically when the alarm is activated. To
open in counterckockwise direction, set dip switch 3 ON.
6.
When the panel is held or meets an obstacle during movement after opening more than 30 degrees, it moves back and tries to advance
once more. If the obstacle is still present panel stops and alarm is heard. Alarm resets after 10 seconds.
7.
If the panel is forced excessively, a built in electronic circuit breaker will be activated and power to motor is disconnected.
In this case a
power off reset is required to restore normal operation.
5. POST INSTALLATION CHECK LIST
No
Item to Check
√
Remarks
1
Installation surface is flat, even and sufficiently strong
2
All wiring is routed and connected properly
3
All AC power lines are properly insulated and grounded
4
Turnstile is positioned and mounted correctly and firmly
5
All anchoring bolts are secured in place with chemical plaster.
6
All anchoring hardware tightened properly (no loose nuts/bolts
etc).
7
Panel, covers, readers etc. are mounted correctly. Panel is
securely bolted in place
8
No physical damage or irregularities (dents, scratches, broken
items ets.)
9
When powered up buzzer is heard, indicator is blue, rotor/panel
in standby position)
10
Turnstile allows passage in A direction (opens clockwise) when
contact is given on Input A and Gnd and indicator turns green.
11
Turnstile allows passage in B direction (opens counterclockwise)
when contact is given on Input B and Gnd and indicator turns
green.
12
Turnstile operates quietly, smoothly and returns to center
(standby) position after the pre-set time elapsed (6 sec default)
13
When Emg contact is given continuously turnstile opens for free
passage..
14
When power is cut off, turnstile allows free passage by pushing
15
AC potential between turnstile ground and neutral is less
than 0.5V. Good continuity (0 Ohm) between chassis and
ground.
Unit is properly grounded.
4.4 Operating Instructions
SN
Access Control Terminal
Res
+24V
B-A
B-A or A-B
A-B
N.O.
N.O.
Com
Com
Gnd
Gnd
Emg
INB
Gnd
Gnd
Gnd
Gnd
INA
1
2
3
7
5
6
8
-
Po
wer
+
B-A
A-B
J3
Top Indicators
Side Indicators
Motor Control
Solenoid Out
Direc
tion Sensors
ON
DipSwitch
1 2 3 4
U2
U7
U1
RL1
RL2
U9
Prg: XXXXXXXXXXX
Rx
Tx
I/O_1
I/O_2
I/O_3
I/O_4
Out_P
3
Out_P
2
Out_P
1
+5
V
+24
V
Gn
d
0.5 - 1 sn
dry contact
or open collector input
888888
Optional counter
1N400
1
or similar
or
or
TRN1202
0.5 - 1 sn
B-A
A-B
Enable
Gnd
Passage confirmation dry contact output
Use with access control systems, counters etc.
accessories (0.5 sec. N.O. contact)
Res: Manual Time Reset (Optional)
24 VDC
Optional counter
sample connection
Emg: Emergency-Free Access Mode
(when contact is open.)
Gnd