On Receipt of New Safe
Inserting Battery

• The Safe will be received in open condition. Emergency Keys, Batteries, Manual &  
  Warranty Card are provided in the polybag kept inside the safe.
• Insert the 4 x 1.5 V Batteries (AA Type) inside the battery compartment.
• Remove the cover and insert the battery and close the battery compartment.  
• Now enter your 3 to 6 digits personal code & then press “ # “.

Four Modes to Open a Safe:
A) CARD SWIPE 

• In open position, steadily swipe the card from right to left. The Safe gets locked and 

the card is well registered.  The display will show “CLOSE”

• To open the Safe, swipe the card right to left again, the display shows “OPENED” & 

the door will open 

B) USER CODE

• Ozone Digital Safes come with Factory Set USER code, 123456 for your security.
• Place the batteries and set your own user code of 3 to 6 digit & then press “ # “.
• The Safe will open with a display 'OPENED'.
• The screen display will show “CLOSED” and the new code is registered successfully.

To change User Code:  
• In open position, press 3 to 6 digits of New User code & then press “#”. The display will 

show “CLOSE”.

• The new user code is now registered.

C) MASTER CODE

To open the Safe with Master Code: 
• In Closed position, enter factory set Master Code 888888. The LED will display 

“PASS9, PASS8…….PASS1”, and the Safe door will open immediately.

To change Master Code:  
• Enter the Master Code. The LED will display “PASS9, PASS8…….PASS1”. Before 

completion of 9 second, press “#”, immediately enter new master code of maximum 6 
digits and again press “#”. The display will show “DONE”

PLEASE NOTE

• In case of wrong no. input, please press “ * “ to cancel. 
• In case of wrong user code input, LED will display “ERROR”

D) EMERGENCY KEYS

• In case of emergency or you forgot User Code/Master Code or batteries got weak etc,  
   the Safe can be opened by Emergency key provided along with the Safe in the kit.  
• When the door is opened, please take the emergency key out in time.
• And at the same time, the user code & master code will return back in “Factory Set 

Codes”