Instructions
•
Insert into socket with wire and voltage meter.
•
Turn on the power. It is not recommended to use the machine for continuous work
as long work time will burn the machine.
•
Set the disinfection time you want; the longest working time is 120 minutes.
•
Do not smell the ozone directly.
Maintenance & Notes
•
If your environment is not in a good condition, you should clean the ozone discharge
plate frequently. We suggest you to clean it once every 3-6 months.
•
When used for air purification, it is advised that people should leave the sterilization
area in case of respiratory system stimulation because of high density of ozone.
•
This unit should operate in a dry and ventilated spaces. Please shield it from direct
sunshine and rain, if it must work outside.
•
Shut off the power if it is not used for a long time.
Troubleshooting
No. General Failure
Failure Analysis
Solution
1
Power indicator off
No power
Connect the power
Fuse damaged
Replace the fuse
Indicator damaged Replace the indicator
2
Operation indicator
off
No power
Connect the power
Fuse damaged
Replace the fuse
Indicator damaged Replace the indicator
3
No ozone output
Discharge bad bulb
Replace the discharge ozone plate
or control circuit board
Ozone plate
damaged
Ozone power
damaged
4
Small amount of
ozone
Discharge aged
plate
Replace the discharge plate
Ozone plate dirty
Open the device and clear the plate
with alcohol and soft cloth
Fan is not working
Replace the fan