Select the most advantageous position for the panels on the roof that spaces the panels equally about roof raft-
ers. Mark a point on the nose of a tile in line with the left hand rafter to represent the bottom of the left hand
panel
For single panel system.
Select a position for the panel which spans 3 rafters and mark a spot on a tile, just above its nose, which repre-
sents the bottom left corner of the panel.
Remove two tiles above the one which was marked over the left hand rafter. Repeat this at the right hand raft-
er.
Slide a Mounting strap onto each end of the support angle and attach the left hand one to the rafter.
Set the angle to a 10mm rise and attach the right hand strap to the rafter. Refit the tiles.
Sit the panel onto the support angle and centralize it. Attach the panel to the angle with the screws provided.
Attach a mounting strap to the centre of the top of the panel.
Remove two tiles from beneath the strap and fasten the strap to the rafter.
Refit the tiles.
For two panel system – Tile Roof
Remove two tiles above the one that has been marked. Remove another two tiles, at the same height as the first
two, from above the rafter which is 1800mm to the right
Slide a mounting strap onto each end of the support angle and attach them to the exposed rafters so that there
is a 15mm rise along the angle. Note that the straps may need to be twisted below the level of the tiles and be
attached to the side of the rafter if there is insufficient room on top of the rafter.
Refit the tiles. Set the panels onto the support angle, centralize them, and tighten up the compression unions
between them.
Using the screws provided, attach the support angle to the panels.
Remove two tiles from above the rafter at the top of each panel.
Attach a mounting strap to the panel in line with the rafter and then attach the straps to the rafters.
Refit the tiles.
For three panel system – Tile Roof
Duplicate the above procedure for the first two panels and then attach the support angle extension to the bot-
tom of the second panel with a 100mm overlap.
Remove two tiles from above the rafter which the extension crosses. Slide the mounting strap onto the support
angle and attach it to the rafter as above, maintaining the upward slope of the support rail.
Refit the tiles and slide the third panel along the rail into contact with No. 2 panel and tighten the compression
unions.