F7. HEATER BOOSTER ELEMENT
Our single element mains pressure hot water storage cylinders have the element midway up the cylinder. The
element is required to boost the temperature of the water to a minimum of 60 degrees celsius. Our cylinders
have an adjustable thermostat which can be adjusted with a flat head screwdriver. This should only be per-
formed by qualified persons. All heater boosters must be fitted with an isolating switch in the metre box during
installation.
WARNING:
The element cover must only be removed by an electrician. The electrical power supply must be de-
activated at the main switchboard before the water heater electrical cover is removed.
BOOSTER ELEMENT / THERMOSTAT / THERMOSTAT BRACKET - FITTING
6
7
Step 1. Remove the housing cover by removing 2 screws.
Step 2. Open housing with views of
4 mounting studs
Step 3. Insert element curve facing up
& with rubber seal loose on element
Step 4.Insert rubber seal between
element mounting studs.
Ensure it’s located properly into the tank.
Step 5. Attach thermostat bracket and
nuts. Tighten nuts securely & evenly.