background image

CHANGING THE GAS SYSTEM

  

 

CHANGING THE GAS SYSTEM 

 

The appliances is designed for operating with the use of LPG or network natural 

gas. The appliances should be operated according to the system installed by the 

authorized service (LPG or natural gas). If the gas system must be changed this 

should only be CARRIED OUT by authorized service personnel. MANUFACTURER 

is not responsible for any problem due to any gas systems changed by people 

except for authorized service personnel. In this case ,the appliances will not be 

covered by the guarantee. On the label at gas inlet it is specified at which gas 

system the appliances operates. 

LIFE OF USE 

 

Appliancess life of use is 10 year if it is used under recommended 

conditions. 

15/16 

SAMPLE LABEL 

CONSUMPTION

NATURAL GAS(G20)

LPG(G30)

PRESSURE=21 mbar

PRESSURE=30 mbar

OSOG 4090

16

1,68 m³/h

1,25 kg/h

OSOG 4090 P

20

2,1 m³/h

1,57 kg/h

OSOG 4090 S 

12

1,26 m³/h

0,94 kg/h

OSOG 8090

32

3,35 m³/h

2,51 kg/h

OSOG 8090 C

10

1,04 m³/h

0,78kg/h

OSOG 8090 P

40

4,19 m³/h

3,14 kg/h

OSOG 8090 T

14

1,46 m³/h

1,10 kg/h

OSOG 12090

48

5,03 m³/h

3,77 kg/h

OSOG 12090 C

30

3,14 m³/h

2,35 kg/h

OSOG 12090 P

52

5,45 m³/h

4,08 kg/h

TYPE

POWER ( KW )

Summary of Contents for OSOG 12090

Page 1: ...y k ekmece Istanbul TURKEY Phone 0090 212 886 78 00 8 Lines Fax 0090 212 886 66 29 Published on 01 01 2013 VER V13 01 1 16 OVER BENCH COOKER WITH GAS USER S MANUAL Web www oztiryakiler com e mail exp...

Page 2: ...DUCTION 4 5 TECHNICAL DATA 6 MAIN DIMENSIONS AND WARNING SIGNS 7 8 SAFETY DETAILS 9 TRANSPORTING AND MOVING 10 11 INSTALLATION OF THE APPLIANCES 12 CONTROL BOARD 13 OPERATION OF THE APPLIANCES 14 CLEA...

Page 3: ...re confused or you don t have enough information please get in touch with authorized service by phone Please keep in mind that if the service personnel is delayed at your site related expenses and del...

Page 4: ...3 13 2 3 3 2X2 2X3 3 10 6 2 2 4 3 3 3 3 6 6 HEAT POWER KW H i Q min 4 10 14 4X10 40 10 2X6 2X10 32 6 6 12 10 10 20 HEAT POWER Q N KW COOKER OVEN 800X900X280 800X900X280 800X900X280 800X900X280 400X90...

Page 5: ...0 48 1200X900X 280 OSOG 12090 R R GAS INLET inch TYPE 2X2 4X3 3 17 2 2X3 3 3 3 9 9 HEAT POWER KW H i Qmin 2X6 4X10 52 2X10 10 30 HEAT POWER Q N KW COOKER OVEN 120X900X280 1200X900X 280 DIMENSIONS mm O...

Page 6: ...MAIN DIMENSIONS AND WARNING SIGNS Figure 1 Main Dimensions and Warning Signs 6 16 HOT SURFACE SAMPLE LABEL...

Page 7: ...aterials cutting blocks curtains etc should never be held near the appliances You can use this appliances simultaneously together with other products of ours The appliances should not be immersed in w...

Page 8: ...e power switches and use a fire extinguisher Never use water to extinguish the fire water will cause the fire to spread more faster Oil spilled on the ground during use must be wiped away Otherwise it...

Page 9: ...rted distance is far the machine should be moved slowly and the appliances should be fixed on the palette or supported in order to prevent jolt Do not hit or drop the products when moving CHANGING THE...

Page 10: ...ppliances should be ensured to operate in a leveled position All of the gas connections of the appliances should complying with ISO 7 1 or ISO 228 1 Gas connections of the appliances should be carried...

Page 11: ...ng the appliances INSTALLATION OF THE APPLIANCES 11 16 Nominal power of the device cannot be changed upon customers request Any modification made on valves and injectors leaves the device out of warra...

Page 12: ...CONTROL BOARD A SAFETY VALVE 12 16 A Back Cooker A Front Cooker...

Page 13: ...al specifications and who has read the instruction manual B TURNING THE DEVICE ON 1 IGNITING GAS BURNER In order to ignite the gas burner bring safety valve A to on position Wait at this position for...

Page 14: ...Please follow the instructions below a Injectors Injector opening should be completely clean b Air adjustment ring It should be clean and not clogged Air mixer should always be set by authorized tech...

Page 15: ...this case the appliances will not be covered by the guarantee On the label at gas inlet it is specified at which gas system the appliances operates LIFE OF USE Appliancess life of use is 10 year if it...

Page 16: ...nd the type of the appliance serial numbers printed on the warranty document are scraped rubbed or changed then the warranty is not valid 6 The warranty covers only maintenance and repairing of materi...

Reviews: