PROBLEMS AND SOLUTIONS

 

PROBLEMS 

PROBABLE CAUSES 

SOLUTIONS 

Leakage from the nozzle 

 

Presence of impurities

 

Gun seat worn out

 

Clean 
Replace the seat

 

Fit adequate filters and/or check 

Leaking  seals

 

Seals worn out

 

Replace seal 

 

Difficult trigger opening

 

High pressure inside circuit

 

Check the bypass valve and adjust it if necessary

 

 

 
REGULATIONS 

The design and construction of our products comply with: norm CEI EN 60335-2-79 first edition, published in 
1999-03 and its respective variations on the project norm prEN 1829.

 

 
Read this manual before starting the assembly. 
For  a  correct  utilization,  follow  the  directions  described  in  this  manual  and  re-print  them  on  the  Use  and maintenance 
manual of the machine. 
 
The present manual is valid for all the guns named 

RL 60. 

SPARES 

Use original PA spares only in order to get both a correct operation and a long lasting, reliable product. 

 

 

MAINTENANCE 

Maintenance has to be carried out by 

Specialized Technicians. 

 
STANDARD:  every  400  working  hours  (circa  10,000  cycles),  check  and  lubricate  the  seals  with  water 
resistant grease. 

 

SPECIAL: every 800 working hours( circa 20,000 cycles), check the wear of the seals and internal parts and 
if  necessary,  replace  with  original  PA  parts,  taking  care  during  installation  to  lubricate  with  water  resistant 
grease. 

 

 

CAUTION:

 re-assemble the gun restoring the original conditions. 

 
The  manufacturer  is not to  be  considered  responsable for  damage  as  a  result  from  incorrect  fitting 
and maintenance.

 

 
Technical data, descriptions and illustrations are indicative and liable to modification without notice. 

 

Reviews: