background image

 

DLF – 

DLF is a set of filters tuned specifically to make recorded music sound more dynamic at low levels.  In the ‘music’ presets on 

the amplifier, this option is turned on. 

High Pass Filter – 

All of the cabinets already have a high pass filter programmed in, but an extra high pass filter is provided to the 

user for crossover, or extra subsonic filtering. 

5 Band Parametric EQ – 

Q factors up to 10 are available to give the user complete control over the sound of their system. 

Mute – 

Controls for system mute, and low and high mute are available to the user. 

4.5.

 

PROTECTION 

In installation, or when the operator is away from the desk, it is understandable that protection will be desired to ensure other 
users do not get unwanted access.  If the LOCK button is pressed, a password prompt will be shown.  

To block use to all features of the software (only signal monitoring will be seen), please use the password: 

dspamp

 

For advanced users only (not recommended):

 to gain access to the individual processing for the transducer components, please 

use password: 

outamp

 

For very advanced users only (not recommended):

 to gain access to master compressor/limiter settings, please use password:

 

limamp 

For standard use, presets 1-4 and 8 are locked by the factory.  Should the user wish to store any additional presets, it is possible 
to do so in slots 5,6,7.  This is done by editing the preset as required, and pressing the store button.  Attempting to store the preset 
in any other slot will result in an error message. 

 

Summary of Contents for XT Series

Page 1: ...P AUDIO XT SERIES MANUAL...

Page 2: ...system s installer AND end user 3 This manual must be read and understood and ALL warnings must be followed 4 Follow all instructions to insure optimal product performance 5 The XT Active products are...

Page 3: ...design and operation of this advanced active speaker system The XT Series of products is designed for both installation and portable truly professional sound reinforcement systems The XT series of mi...

Page 4: ...1 1 x 16 5 x 23 2inches 538 x 650 x 650mm 21 2 x 25 6 x 25 6inches 538 x 650 x 650mm 21 2 x 25 6 x 25 6inches Acoustic Specifications Sensitivity 92dB 93dB 95dB 95dB 97dB N A 98dB N A Frequency Respon...

Page 5: ...h Switch Mode Power Supply N A Class D with Switch Mode Power Supply Protection N A N A N A N A N A Turn On Delay Short Circuit Protection DC Voltage Protection Peak Voltage Limiter Over Temperature P...

Page 6: ...cceptable voltage range is 85VAC 265VAC The amplifier s switch mode power supply SMPS will automatically adjust to the mains voltage present The powered XT enclosures use a standard IEC type connector...

Page 7: ...h male and female XLR type connectors and speakon connectors Any standard XLR type cable end connectors may be used The image below illustrates the inputs found on the amplifier plate Line Input and L...

Page 8: ...log screen will appear checking options for connecting to the device in question To ensure communication occurs on the right COM cable this must be selected from the drop down list For linking between...

Page 9: ...nal preset file must be used to recover the data Recall Loads a preset from the amplifier memory remotely This allows presets to be changed on units in inaccessible locations However once the COM cabl...

Page 10: ...ble that protection will be desired to ensure other users do not get unwanted access If the LOCK button is pressed a password prompt will be shown To block use to all features of the software only sig...

Page 11: ...be monitored if system distortion is present PROBLEM Distorted sound When input levels to the XT amplifiers exceed 0 775 V RMS for line level inputs it is possible to produce system clipping or overdr...

Page 12: ...power amplifier THE INTERNAL FUSE IS NOT USER REPLACABLE UNDER NO CIRCUMSTANCES SHOULD THE AMPLIFIER PANEL BE REMOVED FROM THE CABINET Care should be exercised when disconnecting the amplifier module...

Reviews: