4.5  communication via eWs box

The communication of the Wallbox Duo with the electric vehicle takes place 
via the integrated Schletter EWS Box P. The EWS Box P communication module 
undertakes all control and signaling functions necessary, in accordance with 
IEC 61851-1 Mode 3, for the connection of an electric vehicle (EV) to a cable-
linked supply unit (EVSE). Parameters for a self-sufficient or for a systems-
integrated operation can be configured via HTML pages. The RFID cards can be 
activated or blocked on this HTML page. For more information, please refer to 
the Schletter GmbH website, especially to the links specified under 10. Links 
for support.

4.6.  technical Data (inDepenDent of variant)

color schemes

• 

Body RAL 9003

• 

Housing coating RAL 9003

• 

Front housing / facing RAL 6018

• 

Custom color schemes on request

Dimensions / Weight

• 

W / H / D: approx. 700 x 335 x 170 mm

• 

Weight (variant specific): approx. 17 kg

installation anD assembly

• 

Wall mounting

• 

Recommended installation height: 1300 mm (above top ground surface)

• 

On-wall and in-wall cable routing

• 

Suitable for interior and exterior locations

electrotechnical Data

• 

Nominal power configurable: 10A, 13A, 16A, 20A, 32A

• 

Mains frequency: 50 Hz

• 

Nominal voltage: 230/400V AC

• 

Terminal clamps: 10mm² (L1, L2, L3, N, PE)

• 

Overvoltage category III

• 

Possible integration of customer-installed ventilation system

• 

Charging mode in accordance with IEC 61851-1 (Mode 3)

• 

Ethernet connection (RJ45)

• 

Charging capacity per charging outlet: 11kW (max. 2 x 11kW possible)

• 

Fault current protection 

RCBO Type A, C Characteristic, 

with over-current release 

Rated residual current IΔn 30 mA

• 

Installation contactor 

Rated operating voltage 440V 

   

Rated operational current 24A

• 

Energy meter pulse counter   Alternating current 3 x 65 A, 1000 impulse/kWh, 
with S0 interface 

Accuracy class 1/B

• 

Power supply/control voltage  Output voltage 12V / nominal power 36W

Summary of Contents for Wallbox Duo

Page 1: ...Compact design for wall mounting for various areas of operation Instruction Manual Updated11 2013 Image P CHARGE Wallbox Duo RFID Image P CHARGE Wallbox Duo push buttons Please keep these instructions...

Page 2: ...elements 8 4 3 Electrical components 9 4 4 Socket equipment 9 4 5 Communication via EWS Box 10 4 6 Technical data independent of variant 10 4 7 Technical data independent of equipment 11 5 Installatio...

Page 3: ...l Updated11 2013 3 24 8 General information 20 8 1 Rating plate 20 8 2 Service notes 20 8 3 Trouble shooting 20 9 Conformity 22 9 1 Associated guidelines and standards 22 10 Links for support 23 11 Se...

Page 4: ...er additional functionality Working in conjunction with the SmartPvCharge or another embedded system the electric vehicle can be charged using surplus PV energy only if so required Systems such as cha...

Page 5: ...ecognize potential hazards 2 3 Person instructed in electrics The operation of the P CHARGE Wallbox Duo must be driven by a person who is fully conversant with the electrics of the system and in full...

Page 6: ...taller Warning Danger of suffocation asphyxiation Charging gassing batteries in an interior space can lead to asphyxiation According to the IEC 61851 1 the customer installed exhaust ventilation syste...

Page 7: ...on must be observed 3 Scope of delivery Please first check the physical condition of your delivered product and en sure that it is complete Please do not throw the package as this may result in damage...

Page 8: ...use of economi cal night time energy or time apportioned prioritized fleet management This functionality is only available if the Wallbox is connected to a server Left charging socket RFID card reader...

Page 9: ...er phase 100 Imp kWh Pulsation according to output kWh Consumption is displayed in kWh units L1 L2 L3 With P U I or error message the relative phase is displayed Error With missing phases or incorrect...

Page 10: ...request Dimensions Weight W H D approx 700 x 335 x 170 mm Weight variant specific approx 17 kg Installation and assembly Wall mounting Recommended installation height 1300 mm above top ground surface...

Page 11: ...60 hPa 4 7 technical Data inDepenDent of eQuipment variant e car basic e car mixed e car premium variant e car basic e car mixed e car premium item no 261010 000 261010 300 261010 400 item no 261010 0...

Page 12: ...t in damage to cabling particularly to cable strings leading to the charging sockets 5 4 Preparing the Wallbox Duo Open the front cover to the Wallbox by turning the key in the lock located on the und...

Page 13: ...ful dust amount protection against splashing water from any direction is safeguarded following mounting and installation of the cable entry glands i e appropriate cable entries must be used Cable glan...

Page 14: ...10 0mm Ensure that the holes are drilled to a sufficient depth to receive the wall plugs dowels 3 Fit each of the 6 M8x100 wafer head screws with a sealing rubber washer Position the cable bushing op...

Page 15: ...ar panel 2 Next push the housing from the front up and over the rear panel Position the housing carefully to ensure that the slots fit around the respective cable bushings of the electrical components...

Page 16: ...puter laptop via Ethernet and the EWS Box has to be configured properly For more detailed information on these EWS Box configuration settings please refer to the Links for support stated in Chapter 10...

Page 17: ...lash Press the green flashing button to start the charging process The button is backlit in green throughout the entire charging process terminate charging process step 1 To end a charging session hol...

Page 18: ...tions under Chapter 4 Installation System parameters Start charging process Step 1 To start a charging session plug the cable for the electric vehicle into the ap propriate charging socket Step 2 The...

Page 19: ...icle into the ap propriate charging socket Step 2 The Optimized Charging process is selected by pressing Button 2 or 5 respectively Depending on the parameters chosen for server connection the chargin...

Page 20: ...t intervals Type of function ality audit Inspector Electrical plants and fixed electrical installations in special installations or locations DIN VDE 0100 Group 700 1 year for an orderly condition Qua...

Page 21: ...EWS Box pins may not be correct In this case please contact your service partner Error Activate contactor Here there is a faulty contact in the EWS Box in the contactor terminal X102 at contactor EV 1...

Page 22: ...mmunity test IEC 61000 4 2 2009 and or EN 61000 4 2 Testing and measurement techniques Electrostatic discharge immunity test IEC 61000 2 2 2002 and or EN 61000 2 2 Environment Compatibility levels for...

Page 23: ...tructions_V1_I800025GB pdf EWS Box Quick guide to operations HTML configuration www schletter de EN download traffic engineering ews box html P CHARGE_EWS Box_ _Administration_V1_I800024GB pdf EWS Box...

Page 24: ...In the event of a warranty claim the company Schletter GmbH shall bear the costs required for transport travel labour and materials only excluded are the additional and potentially substantial costs i...

Reviews: