background image

         

  

 

                                 

www.pmlighting.com 

  

                info@pmlighting.com  

 

 

Easy Design Guide 

Use the Easy Design Guide to help determine the best way to wire your fixtures to create optimal results in the 

illumination of your home. Follow these simple rules for best results: 

1.

 

It is recommended that you use 

2 MAIN SUPPLY CABLE

 runs from the transformer for best results and 

easiest installation, especially when you need to install fixtures on both sides of the transformer.    

 

2.

 

For short distances from the transformer (under 60 feet), only a single

 MAIN SUPPLY CABLE 

may be used to 

install this LED system for even easier installation. If the transformer is located on one end of the house, 

simply run a cable from the transformer to the various lights, leaving a little extra slack to make burying the 

cable easy.  

 

3.

 

DO NOT EXCEED the MAXIMUM WATTAGE

 listed for each length of MAIN SUPPLY CABLE used or the 

voltage at the fixtures will be lower than required causing the LED to flicker or not light at all. If any lights, 

especially  on the end of the 

MAIN SUPPLY CABLE, 

do not light or experiences flickering, make sure the 

transformer is on the HIGH setting (See #4 below) and check to make sure the quick connectors on each 

light fixture  are properly installed and are making a good connection. 

 

4.

 

Use the 

HIGH SETTING

 on the transformer to boost the secondary voltage for this system to provide 

additional voltage. (See details in Transformer Installation Sheet) 

 

5.

 

SHORTER lengths for the MAIN SUPPLY CABLE lowers

 voltage drop on the line while 

LONGER lengths 

increases

 the voltage drop. Use the Line Length/Wattage Chart below to determine the maximum wattage 

load for various lengths of the MAIN SUPPLY CABLE.  

 

6.

 

The total wattage for the CS9

ϯ

00-LED 9-Light System is only  

55

 watts

, providing ample room on the 

standard 100 watt transformer to add additional CS Professional Series LED fixtures to expand your system. 

The chart below will help determine the maximum amount of fixtures you can have on the system when you 

add up the total wattage from all fixtures on the line / system.    

   

Total Length of Main 

Supply Cable  

Maximum Wattage 

Available for Fixtures  

 

 CS9

ϯ

00-LED Fixtures & 

Optional Add-ons  

Individual Fixture 

Wattage  

50 Feet 

90 watts 

 

CS936-LED Path Light 

3.0 watts 

60 Feet  

75 watts 

 

CS937-LED Bullet Light 

5.0 watts 

70 Feet 

60 watts 

 

CS938-LED Deck Light* 

ϯ͘Ϭ

 watts 

80 Feet 

55 watts 

 

CS933-LED Well Light 

9

͘Ϭ

 watts 

90 Feet 

50 watts 

 

*Sold Separately - Optional add-on fixtures are   

100 Feet 

45 watts 

 

   

ŶŽƚŝ

ncluded in the CS9

ϯ

00-LED 9-Light System. 

Save these instructions! 

CS9

3

00 Professional

 

Series

 

LED Landscape Lighting System 

– 

pg. 2

 

Summary of Contents for Professional CS9300-LED

Page 1: ...www pmlighting com info pmlighting com Installation Manual CS9300 LED Professional Series Landscape Lighting System...

Page 2: ...te easy to install and is much easier than traditional halogen systems LED lighting allows the running of cables with less complications of the dreaded voltage drop that occurs more readily with halog...

Page 3: ...fixture are properly installed and are making a good connection 4 Use the HIGH SETTING on the transformer to boost the secondary voltage for this system to provide additional voltage See details in T...

Page 4: ...rom the transformer to split the fixtures into two 2 groups For best results follow these tips 1 Keep cables as short as possible 2 Leave enough slack to make burying cable easier 3 Make sure the Easy...

Page 5: ...persons Keep away from combustibles Lamp gets hot very quickly Turn off or unplug luminaire and allow lamp to cool to change bulb When using high wattage lamps keep luminaire away from children as lu...

Page 6: ...ire away from children as luminaire may become VERY HOT Do not install luminaire within 10 feet 3 05 meters of a pool spa fountain or pond Do not cover or bury luminaire and keep luminaire clear of de...

Page 7: ...Y HOT Do not install luminaire within 10 feet 3 05 meters of a pool spa fountain or pond Do not cover or bury luminaire and keep luminaire clear of debris Use only UL compliant components including lo...

Page 8: ...Cut the old Quick Connect parts from the wires if replacing old ones and strip the end of the wires to approximately in length 2 Use the wire nuts included in the replacement kit to connect each side...

Page 9: ...www pmlighting com info pmlighting com CS9100 Professional Series Landscape Lighting System pg 8...

Page 10: ...ING UP TO 2 MAIN CABLE RUNS 3 ATTACH ONE SIDE OF THE MAIN CABLE RUN TO THE LEFT TERMINAL 1 BY INSERTING THE STRIPPED WIRE APPROX INTO THE BOTTOM OF THE TERMINAL BLOCK ATTACH THE OTHER SIDE OF THE MAIN...

Page 11: ...www pmlighting com info pmlighting com CS9100 Professional Series Landscape Lighting System pg 10...

Page 12: ...www pmlighting com info pmlighting com P O Box 98 Ashland City TN 37015 Phone 615 792 6884 Fax 615 792 6898 2016 P M Lighting LLC All Rights Reserved...

Reviews: