Genpower Ltd confirms that this P1PE product conforms to the following CE directives: 
2006/42/EC Machinery Directive 
2004/108/EC EMC Directive 
2000/14/EC Noise Emissions Directive 
97/68/EC NRMM Emissions Directive 

 

EC DECLARATION OF CONFORMITY 

 

The undersigned. As authorised by: 

Genpower Ltd 

 

Conforms to the Directive:- 

2000/14/EC (as amended) 

 

Of the European Parliament and of the council on the approximation of the laws of the Member 
States relating to the noise emission in the environment by equipment for the use outdoors. 

 

Equipment Category: 

Power Equipment 

 

Product Name/Model: 

P1PE P2000iLPG 

 

Type/Serial No: 

Inverter Generator 

 

Net installed power: 

1.6kW 

 

The technical documentation is kept by: 

Roland Llewellin, Genpower Ltd 
Isaac Way, Pembroke Dock, 
Pembrokeshire, SA72 4RW. 

The conformity assessment procedure followed was in accordance with annex V of the Directive. 

Notified Body: 

AV Technology Ltd, Unit 12 Easter Court, 
Europa Boulevard, Warrington, Cheshire. WA5 7ZB 

 

Measured Sound Power Level: 

68dB 

 

Guaranteed Sound Power Level: 

68dB 

 

A copy of this certificate has been submitted to the European Commission and the EU Member 
State United Kingdom. 

 

Place of Declaration: 

Pembroke Dock, SA73 4RW 

 

Date: 

07/03/2018 

 

Signed by: 

Roland Llewellin 

 

Position in Company: 

Managing Director 

 

Name and address of manufacturer or Authorised representative: 

 

Genpower Ltd 
Isaac Way, Pembroke Dock, 
Pembrokeshire, SA72 4RW 

DECLARATION OF CONFORMITY 

Summary of Contents for P2000iLPG

Page 1: ...FOR YOUR SAFETY You must read and understand this manual before use Keep this manual for future reference...

Page 2: ...rical System 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 AC Parallel Operation 15 Don...

Page 3: ...Oil Capacity 350ml 11 8oz Fuel Tank Capacity 4 5L 1 18Gal See Oil Recommendations in the maintenance section Maximumwattageandcurrentaresubjectto andlimitedby suchfactorsas fuelBTUcontent ambienttemp...

Page 4: ...gas is a poisonous odourless gas that can cause headache confusion fatigue nausea fainting sickness seizures or death If you start to experience any of these symptoms IMMEDIATELY get fresh air and see...

Page 5: ...overing to contain long hair When adding or draining fuel unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running then the fuel cap is under pressure...

Page 6: ...ARNING Only operate generator on a levelsurface Always connect the nut and ground terminalon the frame to an appropriate ground Generatormustbeproperlygroundedtopreventelectrocution WARNING WARNING Ne...

Page 7: ...FEATURES 1 2 3 4 5 6 7 8 9 11 12 10 20 19 13 14 18 15 16 17...

Page 8: ...arninglightdoesnotcomeonandtheengine stalls turn the Start Switch to RUN and pull the recoil starter handle Engine Overload Indicator Light If the engine overload light comes on the generator wattage...

Page 9: ...dicator ACPilot Indicator Engine Economy Control When the Engine Economy switch is turned to the ON position the economy control unit automatically determines the generator s proper engine speed based...

Page 10: ...Terminal The generator s ground terminal must always be used to connect the generator to a driven ground rod Connect the ground terminal to thedriven ground rod with a No 12 AWG American Wire Gage cop...

Page 11: ...ng fuel Do not overfill the fuel tank Provide space for fuel expansion Turn cap counter clockwise to remove ASSEMBLY Never handle the generator electronic devices or any cord while standing in water w...

Page 12: ...unt of semi synthetic SAE 10W 30 engine oil until the oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick and securely tighten before attempting to star...

Page 13: ...eft to LPG Screw the Propane hose to the Panel Propane Connection DO NOT Pull the choke lever out Turn on the propane supply Press the decompression valve button for 3 to 5 seconds Pull recoil handle...

Page 14: ...ee page 10 for instructions Make sure the attached load is within the generator rated output and the receptacle s rated current Make sure all electrical cords and sockets are in good condition Make su...

Page 15: ...its rated wattage to start This additional power is referred to as surge watts and usually lasts between 2 3 seconds When an electronic device is started the red overload indicator may come on This i...

Page 16: ...r m Saw 2000 2000 Gas Clothes D r y e r 700 2500 Electric D r ill HP 5 4 Amps 600 900 Don t Overload Generator Make sure you can supply enough rated watts for all electronic devices connected to the...

Page 17: ...ty conditions Service Spark Plug 12 Months 300 hr Use Clean Fuel Filter Replace if necessary Check Crankcase Breather Hose for cracks or damage Replace if necessary De carbonize cylinder head See deal...

Page 18: ...028 in if necessary Reinstall spark plug and tighten to Torque 20 0Nm 14 8ft lb If spark plug is worn replace only with an equivalent replacement part Spark plug should be replaced annually Reconnect...

Page 19: ...lect used oil Allow oil to drain completely Return generator to a level surface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall outer casing sid...

Page 20: ...ark Check themufflerscreenand spark for carbon deposits Remove carbon deposits with a wire brush Check themufflerscreenand spark for damage Ifdamaged replacewith P1PE replacement parts Install the spa...

Page 21: ...tor level to prevent fuel spillage Fuel vapor or spilled fuel may ignite Remove any debris that has collected on the generator and around the exhaust and control panel Use a brush or vacuum to remove...

Page 22: ...trol from the generator into a petrol approved container Wipe up any spilled fuel with a clean rag Start generator engine and let it run until it stops and all remaining fuel is consumed Do not connec...

Page 23: ...Contact service department Engine will not start shuts down during operation or starts and runs rough 1 Choke set to OFF 4 Out of fuel or Stale fuel 5 Sparkplugwiredisconnected from spark plug 6 Bad...

Page 24: ...24 RECYCLING PRODUCTDISPOSAL WIRING DIAGRA...

Page 25: ...erter Generator Net installed power 1 6kW The technical documentation is kept by Roland Llewellin Genpower Ltd Isaac Way Pembroke Dock Pembrokeshire SA72 4RW The conformity assessment procedure follow...

Page 26: ...LondonRoad PembrokeDock Pembrokeshire SA724RW UK TELEPHONE 44 0 1646687880 FAX 44 0 0164686198 WEBSITE www pipe co uk To register your machine for the manufacturer s warranty please visit http www p1p...

Page 27: ......

Page 28: ...P1 PE Position One Power Equipment Isaac Way Pembroke Dock Pembrokeshire SA724RW www p1pe co uk...

Reviews: