OWNERS MANUAL 

Congratulations on the purchase of your bathtub! 

 

BOLERO 
 

Please read and follow all the instructions contained in this Owners Manual before installing your 
bathtub. In addition, you should refer to these instructions during the life of your bathtub. 

 

 

Instruction for bathtub installation 

Only a qualified serviceman should perform the installation of your bathtub. 

 
Preparation of area 
As the front panel of the tub must be freely moved either during the installation or exploitation, choose the right 
area in which to install the bathtub. 
Prepare the floor and walls before installation works. The corner in which the tub will be installed, as well as the 
walls must be in straight angle against to floor to avoid possible gaps between tub and wall. 
The place under the tub must be in the same level as the floor. 
All drain connections should fit in between bathtub and its legs (see the drawing).  
The centre of drain is pointed in the drawing. Before assembling connections check the inlet of drainage (Ø 50 
mm); it must be either in the same level or maximum 50 mm from the floor and not closer within a radius of 200 
mm from the centre of bathtubs drain outlet (see the drawing). 
In case the mixers are installed on the edge of the tub outlet pipes for hot and cold water with the ½” treads 
must be arranged under the unit. 
All the models of PAA tubs and whirlpools could be installed in built-in version without front panel. For built-in 
version plan and provide access door for reaching the most significant massage system parts (water pump and 
air blower). Please consult with PAA or its dealers in these cases. 
Also provide the necessary space around the water pump and blower to properly ventilate and cool them during 
operation. For built-in tub there is necessary to plan ventilation access door as well. 
Electrical connection of the whirlpools 
Grounding is required. Connect the tub to 230V, 50Hz wiring connection. Provide to each system proper electric 
power, choose the right crosscut cable. Use for system separate 16A differential safety catch (electric current 
loss max. 30 mA). Advised length for cable is 150 cm. 

Upon receipt, immediately inspect the bathtub to make sure the unit has shipped as ordered and 
has arrived undamaged.

 

If a problem is discovered, call your PAA dealer immediately.   

Handling damages are not covered under warranty.

 