23
TROUBLE
PROBABLE CAUSE
REMEDY
E
The winch runs hot.
1. Same as D1.
2. Be certain that the hydraulic system
temperature is not more than 180
degrees F. Excessive hydraulic oil
temperatures may be caused by:
A. Plugged heat exchanger.
B. Too low or too high oil level in hy-
draulic reservoir.
C. Same as D2.
D. Hydraulic pump not operating ef-
fi ciently.
3. Excessively worn or damaged in-
ternal winch parts.
Same as remedies for Trouble D1.
Thoroughly clean exterior and fl ush inte-
rior.
Fill/drain to proper level.
Same as remedies for Trouble D2.
Prime mover low on horsepower or R.P.M.
Tune/adjust prime mover.
Check suction line for damage.
If pump is belt driven, belts are slipping. Re-
place/tighten belts.
Pump worn. Replace pump.
Disassemble winch to inspect/replace worn
parts.
F
Winch “chatters” while raising
rated load.
1. Same as D2.
2. Hydraulic oil fl ow to motor may be
too low.
3. Controls being operated too quick-
ly.
Same as remedies for Trouble D2.
Same as remedies for Trouble E2.
Conduct operator training as required.
Summary of Contents for BRADEN HP125B