PEC 013
Page
70
of
71
12/20/13
Parameter Name
Number
Min/Max/Default/Units
Timer Setting PTO Mode w/o Park Brake
Set
Page 15
N188
MIN = 5 (MIN)
MAX = 1092 (MIN)
DEFAULT = 15 (MIN)
Reset EIST Timer Base On Engine Load
Page 16
N190
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 1 (Yes)
Expiration Distance
Page 15
N193
MIN = 0 (miles)
MAX = 1,259,000 (miles)
DEFAULT = 500,000 (miles)
EIST Time for Shutdown Warning
Page 15
N194
MIN = 30 (Seconds)
MAX = 255 (Seconds)
DEFAULT = 60 (Seconds)
Enable Accelerator Pedal Reset
Page 15
N197
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 1 (Yes)
Enable Service Brake Rest
Page 16
N198
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 1 (Yes)
Enable Clutch Pedal Reset
Page 16
N199
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 1 (Yes)
Allow EIST Timer Overrules in PTO Mode
Page 16
N200
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 1 (Yes)