PEC 013
Page
12
of
71
12/20/13
Fuel Density
Parameter Name
Number
Min/Max/Default/Units
Fuel Density
N051
MIN = 780 (g/l)
MAX = 950 (g/l)
DEFAULT = 855 (g/l)
Nonprogrammable Parameters
HEST Warning
Parameter Name
Default/Units
HEST Warning Temperature Activation Limit
DEFAULT = 842 (F)
HEST Warning Temperature Deactivation Limit
DEFAULT = 833 (F)
Activate/Deactivate Requirements
HEST Warning
ON (All)
OFF (Any)
Exhaust Temperature > HEST Warning
Temperature Activation Limit
Exhaust Temperature < HEST Warning
Temperature Deactivation Limit
Vehicle speed < HEST Warning Minimum
Vehicle Speed
Vehicle speed > HEST Warning
Maximum Vehicle Speed
Additional information
HEST Warning on the Driver Display
Figure 1 shows an example of a screen on the driver display when the HEST
warning is ON.
Figure 1 - HEST Warning Light