PEC 013
Page
17
of
71
12/20/13
Outside Ambient Air Temperature Override
Parameter Name
Number
Min/Max/Default/Units
Low Ambient Temperature Overrule
N185
MIN = -40(F)
MAX = 491 (F)
DEFAULT = 40 (F)
High Ambient Temperature Overrule
N184
MIN = -40(F)
MAX = 491 (F)
DEFAULT = 80 (F)
Engine Load Override
Parameter Name
Number
Min/Max/Default/Units
Overrule EIST Timer Based on Engine
Load
– No Shutdown
Requirements to enable (N191 = 1)
N190 = 0
Not Available with PTO Mode
N191
MIN = 0 (No)
MAX = 1 (Yes)
DEFAULT = 0 (No)
EIST Engine Load to Reset/Override
N183
MIN = 0 (%)
MAX = 100 (%)
DEFAULT= 35 (%)
Non-Programmable Parameters
Parameter Name
Number
Min/Max/Default/Units
EIST Low Coolant Temperature
Overrule Limit
N182
DEFAULT = 30 (F)
EIST Low Oil Temperature Overrule
Limit
N195