PEC017
5/3/2018
Page
63
of
105
N091
Page
Min
Default
Max
Units
Engine Speed Ramp-down
w/Res/Decel (Remote)
10
250
1000
RPM/SEC
N092
Page
Min
Default
Max
Units
Engine Speed Increase w/Set/Accel
(Remote)
10
50
1000
RPM
N093
Page
Min
Default
Max
Units
Engine Speed Ramp-Up w/Set/Accel
(Remote)
10
250
1000
RPM/SEC
N102
Page
Min
Default
Max
Units
Signal Source for Remote Main
Switch
0
0
1
N/A
* 0 = Hardwired 12V
1 = CAN Signal
N306
Page
Min
Default
Max
Units
Enable Engine Speed Control via
TSC1
OFF (0)
OFF (0)
ON (1)
ON/OFF
N307
Page
Min
Default
Max
Units
Disable In-Cab Accelerator Pedal in
Remote PTO
OFF (0)
OFF (0)
ON (1)
ON/OFF