HVAC: Idle Management System
A/C System Diagnostic
Check service screens before troubleshooting, see
“
NOTE
Removing fuse F1 for 10-15 seconds will reset the sys-
tem controller to factory default settings.
Table 1.
A/C System Diagnostic
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
/
Unit will not run or turn on
Display comes on for 5 sec-
onds, shows service screen
for 3 seconds and then pow-
ers off (see #9)
1. Loose connection.
2. No power is available
at the unit.
3. Blown fuse or fuses.
4. Check Voltage path to
unit and control
5. Defective control
panel.
6. A/C system controller
defective.
7. Broken wire or defec-
tive wire harness.
8. Check for Fault code.
9. Can Buss connection.
10. Ignition switch
1. Confirm all connections are tight, including ground lugs,
and terminals crimped on wires and battery cables.
2. Check
All
batteries for Voltage. Check battery manage-
ment system and separator solenoid. Unit has a low volt-
age disconnect of 11.2 volts.
3. Check all fuses. See “
Figure 18. Internal Wiring Diagram
4. Check for 12 volt through the 100 amp main fuse and F1
10 amp control fuse to controller pin C1. Also see “
Main Controller/Compressor Controller
5. Check control. See “
B. Fan and Temperature Control
6. Test system controller. See “
7. Inspect wiring harness and all ground wires.
8. View faults on the controller. See “ Operation” on
9. Check can bus harness, resisters and connections.
Reset controller. See
18. Internal Wiring Diagram (Before 8/1/2016)
Figure 19. External Wiring Diagram
10. See “
Control Module Pinout with Functional Information
on page 31 (pin D2)
Auxiliary batteries will not
recharge
1. Check battery Man-
agement System.
2. Check Battery Sep-
arator.
1. Check battery management device, harness and sep-
arator. See “
L. Testing the Battery Management System
2. See “