Page
32 of 39
Number
SM001-300
HVAC: Idle Management System
D6
WAKEUP
Blue
Switch to Ground input
from ACU - turns on
Parked unit
9-14V with control off,
<1V when unit on
Blue wire (pin 6) in connector
on back of control
D7
ISO 9141
Brown
Reprogramming
Used for software
upgrades - no normal
function
D8
D9
D10
COMP_RLY
_SIG
White
Switch to Ground
output to relay 3 -
Compressor power
from AUX Batteries
<0.5V if on, otherwise
11-14V
Relay in electrical center
D11
COND_RLY
_SIG
White
Switch to Ground
output to relay 1 -
Condenser fan power
from AUX Batteries
<0.5V if on, otherwise
11-14V
Relay in electrical center
D12
BLWR_RLY
_SIG
White
Switch to Ground
output to relay 2 - Evap
blower power from AUX
Batteries
<0.5V if on, otherwise
11-14V
Relay in electrical center
D13
D14
PROGRAM
_EN
White
Ground input to go into
reprogramming mode
Not normally used
White wire (pin 8) in
connector on back of control
D15
D16
Table 5.
Control Module Pinout with Functional Information
Pin
Circuit ID
Wire Color
Function
Typical Voltage
Other End of Circuit