Page
26 of 39
Number
SM001-300
HVAC: Idle Management System
1. Determine the model of truck to charge the A/C sys-
tem.
Table 3.
Charge Capacity
Model
Size
T680, w/ 76 inch
Sleeper
21.00 oz. (1.31 lbs.)
Above shows tested charge level for current Ken-
worth models. Following the instructions provided
with the recovery station, set the recovery station to
charge the system with the specified amount of
refrigerant.
2. On the recovery station, set the high side valve to
CLOSED, and the low side valve to CHARGE.
3. Press the CHARGE button to start the charge proce-
dure. When the system is fully charged, the recovery
station will turn off.
4. Complete the charging procedure by setting both
hand valves on the recovery station to the CLOSED
position.
5. Close valve on hose at condenser, then disconnect
the blue hose quick-disconnect fitting from the Ken-
worth EHVAC service port.
6. Install the protective cap on the Kenworth EHVAC
service port fitting.