HVAC: Idle Management System
Operation
To start the system push ON/OFF button. Display will
show current mode/ temperature setting / battery level.
See Figure 21.
Initial default setting is blower speed 1/ AUTO- MODE
/60 °F.
Figure 21.
On/Off Button
ON/OFF
Changing MODE – press ENTER, while mode is dis-
played use up or down arrows to select AUTO / COOL /
HEAT. After 5 seconds selection will be set. See Figure
22.
Figure 22.
Changing Mode
ENTER
Changing BLOWER SPEED – press ENTER until display
shows FAN and SPEED. Press up or down arrows to
select 1 - 2 - 3 speed. After 5 seconds selection will be
set. See Figure 23.
Figure 23.
Changing Blower Speeds
ENTER
Changing TEMPERATURE set point. Anytime the tem-
perature set point is displayed on the screen, push the up
or down arrows to change. Temperature range is from 60
°F (coolest) to 85 °F (warmest). See Figure 24.
NOTE
Control will always default to the last setting when the
unit is turned on.
Figure 24.
Changing Temperature
ENTER
To view system runtime/hours – press ENTER until "Hrs"
show on display. When hours are displayed, pressing
ENTER for 7 seconds will reset the hours to zero. See
Figure 25.