PS-90 Tip Installation
For maximum productivity and proper fit, install tips into your soldering iron when the heater is hot
CAUTION:
To avoid burns or potential injury, always hold the handpiece with the heater pointed at an angle
up to prevent injury.
1. Insert the Tip fully into heater bore using the supplied Tip Tool.
2. Gently tighten the heater Set Screw.
3. Recheck the tip Set Screw periodically to insure that it remains
snug.
PS-90 Heater Replacement
If replacement becomes necessary, perform the following procedure to ensure optimum performance and
maximize the life expectancy of the heater.
1. Allow the heater to cool.
2. Remove the Heater Retaining Nut.
3. Pull the Heater Assembly from the Handle. Discard defective Heater Assembly.
4. Align the connector key on the handle end of the replacement Heater Assembly with the keyway slot
on the handle.
5. Push the Heater Assembly fully into the handle.
6. Replace the Heater Retaining Nut and tighten by hand.
Spare Parts
Item #
Description
PACE Part Number
1
PS-90 Flat Ring
1500-0076-P5
2
PS-90 Heater Assembly (also fits PS-80)
6010-0095-P1
3
PS-90 Flared Ring
1500-0074-P5
4
Retaining Nut for PS-70/PS-90
1410-0122-P5
5
Heater Set Screws
1348-0547-P10
NOTE
Periodically, clean the heater bore with a properly sized
wire brush (3/16" O.D. to insure optimum heat transfer
and proper tip grounding when.
Handpiece Connection
Connect the handpiece connector plug into the Power Receptacle
in the following manner.
1. Align guide on connector with slot on power receptacle.
2. Insert connector into power receptacle.
3. Turn the connector housing clockwise to lock in place.
Burn In Procedure
The following Burn In procedure must be performed to insure optimum performance and life
of this product:
1.
Insure that system is located in a well-ventilated area on Initial power up.
2.
Remove plastic cap from end of Heater Assembly (If present).
3.
Connect Handpiece to PACE system Power Source.
4.
Set Handpiece Tip temperature to 316°C (600°F). Burn Handpiece in for 10 minutes at this
temperature.
5.
Set Handpiece Tip Temperature to 427°C (800°F). Heater Assembly will again emit smoke. Burn
Handpiece in at this temperature until emission of smoke ceases. Approximately 15 minutes.
6.
Operate Handpiece in a normal manner.
w w w . e k t