background image

MTS Systems Operation Manual  

©2004 PACE Inc., Annapolis Junction, Maryland 

Page 8 of 11 

All Rights Reserved 

 

 

  

Handpiece Vacuum/Pressure 

 

To set up your Sodr-X-Tractor air hose connection, perform the following steps: 
 

1.   Air Hose To Handpiece Connection 

a)      Attach  one  end  of  a  137cm  (54  inch)  length  of  air  hose  to the 

 

metal 
tube in the back of the handpiece. 

b)   If you have a PACE system incorporating only one handpiece, 

attach the air hose to the power cable using the supplied Hose 
Clamps.    Space  them  evenly  along  the  length  of  the  power 
cable  starting  at  a  point  6  inches  from  the  ends  of  the 
handpiece. 

c)   If  you  have  a  PACE  system  incorporating  2  or  more  air 

handpieces,  you  may  wish  to  leave  the  air  hose  assembly 
unattached to allow a quick change to any air handpiece being 
used. 

 

2.   Prepare a VisiFilter in the following manner: 

a)   Connect  a  1  inch  (2.5cm)  length  of  clear  pvc  air  hose  to  the 

 

FLOW OUT  side  of  the  VisiFilter;  push  and  turn  the  hose  onto 

 

the VisiFilter nipple to seat. 

b)  Insert the ribbed end of a male quick connect hose mount fitting (P/N 1259-0087) into the 

free end of the 1 inch (2.5cm) length of air hose connected to the FLOW OUT side of the 
VisiFilter. 

c)  Connect  the  free  end  of  the  137cm  (54  inch)  length  of  air  hose  to the  FLOW IN  side  of 

the VisiFilter. 

d)  Insert the end of the quick connect hose mount fitting (on VisiFilter FLOW OUT side) into 

the power source Vacuum Port. 

 
3.   When using air pressure, and/or utilizing multiple air handpieces, PACE recommends the 

use  of  the  following  set  up  procedure  which  utilizes  additional  quick  connect  hose 
mount  fittings.  An  assortment  of  quick  connect  air  fittings  are  supplied  with  each 
additional air handpiece. 

a)   Disconnect  the  137cm  (54  inch)  length  of  air  hose  from  the  FLOW  IN  side  of  the 

VisiFilter assembly. Insert the ribbed end of a male quick connect hose mount fitting 
(P/N 1259-0087) into the free end of this air hose. 

b)  Connect the free end  of a 1 inch (2.5cm) length of air hose  with an installed female 

quick  connect  hose  mount  fitting  (P/N  1259-0086)  to  the  FLOW  IN  side  of  the 
VisiFilter Assembly. 

c)  The  137cm  (54  inch)  length  of  air  hose  can  now  be  easily  moved  between  the 

VisiFilter  Assembly  and  the  Controllable  Pressure  Port.    The  VisiFilter  assembly 
remains connected to the Vacuum Port. 

 

4. Additional fittings may also be added to the hose connection at the rear of each air handpiece  
    to ease changing of handpieces. 

 

NOTE:    

When removing any air hose, turn and pull. Do not attempt to pull hose directly off. 

Damage to or breakage of fitting or VisiFilter may occur. Use your Sodr-X-Tractor with 
a clean VisiFilter element. Otherwise a deterioration in performance or damage to the 
unit may occur. 

 
Ensure that only one air hose is connected to the

 VACUUM

 or controllable 

PRESSURE

 port of 

the  same  Flo  Pump  at  one  time.  Attachment  to  both  ports  simultaneously  will  cause 
deterioration in performance. 

Summary of Contents for 8007-0412

Page 1: ...VAC 8007 0414 MTS 200 SC System 230 VAC 8007 0415 MTS 200 SA System 115 VAC 8007 0412 MTS 200 SA System 230 VAC 8007 0413 MTS 300 System 115 VAC 8007 0418 B MTS 300 System 230 VAC 8007 0419 B MTS 350...

Page 2: ...n 4 Safety 5 System Set Up 5 Mounting Options 5 System Power Up 5 Handpieces 6 Handpiece Tip Tool Stands 6 Adjusting the Angle of the Cubby 6 Handpiece Connection 6 Operation of MTS Systems 6 Vacuum P...

Page 3: ...e FH channel the MTS 350 features 1 HC channel and 2 FH channels The system also comes standard with Auto Setback and Auto Off functions to preserve tip life Applicable Regulations MTS systems are ava...

Page 4: ...1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V System 1 Amp TimeBlo 230 V System MTS 350 1 3 Amp 115 VAC 60 Hz Max OR 7 Amp 230 VAC 50 Hz Max Fuse 2 Amp SloBlo 115 V Syst...

Page 5: ...CE systems in a well ventilated area A fume extraction system such as those available from PACE are highly recommended to help protect personnel from solder flux fumes 6 Exercise proper precautions wh...

Page 6: ...ector and handpiece port on the system For example HC handpieces have the red connector and will only connect to red ports Likewise Fixed Heater handpieces have black connectors and can only be connec...

Page 7: ...Features These are pre programmed for 30 minute Auto Setback and 30 minute Auto Off which can be turned off by the switch on the back of the unit If the handpiece channel has not been used for 30 min...

Page 8: ...iFilter FLOW OUT side into the power source Vacuum Port 3 When using air pressure and or utilizing multiple air handpieces PACE recommends the use of the following set up procedure which utilizes addi...

Page 9: ...one of the same rated value Handpiece will not heat Defective Heater Change Tip Cartridge Power Source Malfunction Contact PACE Power Source Corrective Maintenance Packing Contents Description MTS 200...

Page 10: ...WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user...

Page 11: ...BRITE AUTO OFF and TEKLINK The following are registered trademarks and or service marks of PACE Incorporated Annapolis Junction Maryland U S A ARM EVAC FLO D SODR MINIWAVE PACE SENSATEMP SNAP VAC SOD...