©2012 PACE Inc., Vass, North Carolina, All Rights Reserved
Page 2
Introduction
Solder Fume removal when hand soldering is an often-overlooked work place hazard. Medical research has
confirmed an increased incidence of occupational asthma, chronic bronchitis, allergic reactions and other
deleterious health effects to be associated with exposure to solder/flux fumes in the electronics industry.
The PACE Arm-Evac 105 Central Filter Unit represents the latest technology in affordable fume extraction. It
features a brushless motor along with a filtration process which includes a pre-filter for course particle removal,
and a HEPA-Type Particulate/Gas Filter cartridge for efficient filtration. Several types of filters are available:
1) A General Purpose Filter for normal soldering applications.
2) A Clean room Filter for use in clean room environments.
3) An Adhesive Filter for removing fumes produced from light gluing applications.
4) An Economy Foam filter for larger applications such as sanding, bench-top machining & grinding.
5) An Extended Life Filter and High Capacity Pre-Filter for longer maintenance intervals during normal soldering
operations.
The Arm-Evac 105 Fume Extractor uses specially designed extraction accessories that can be conveniently
mounted on any workbench or tabletop. The Arm-Evac 105 can be used to extract fumes from one or two
different work benches/collection points.
Specifications
Arm-Evac 105 System Part Number
8888-0110-P1 for 110V, 60hz unit
8888-0105-P1 for 230V, 50hz unit
Flow Rate with standard filter
Single inlet: 131cfm
Dual Inlet: 70cfm per inlet
Flow Rate with Cleanroom Filter
Single inlet: 122cfm
Dual inlet: 62cfm per inlet
Noise Level
57dbA at 2 meters
Weight
11.5Kg (25.3lbs)
Size H x W x D
362 x 290 x 290mm
(14.25” x 11.5” x 11.5”)
Housing
20 gauge steel (static safe)
Number of inlets
Two 75mm (3”)
# of Collection accessories
Two 65mm (2.5”) or 75mm (3”)
Maximum duct run
2.5m (8’) per inlet
Environmental Specifications
Ambient operating temperature
0ºC to 50º (32ºF to 122ºF)
Storage temperature
-40ºC to 125ºC (-40ºF to 257ºF)
Ambient operating humidity
90% relative humidity max non-condensing
Storage humidity
90% relative humidity max non-condensing