©2012 PACE Inc., Southern Pines North Carolina All Rights Reserved
Page 18 of 20
1
SensaTemp Handpieces – No adjustment possible, select a performance level that
results in the desired temperature.
2
Tip heater Cartridge Handpieces – Use the adjustment screw as described under “To
adjust Dial Temperature Control Systems/Tip heater Cartridge Adjustment.
Corrective Maintenance
Digital Display Message Codes
Listed below are message codes, which, may be shown on the LED Display if a mistake were to be
made by the operator (e.g., wrong Password entry) or if the system has malfunctioned.
LED Display Message
Description
The incorrect password has been entered. The displayed
message will time out after 6 seconds and revert to normal
operation. Enter the correct password.
“Open Sensor Error” No handpiece is connected to the power
receptacle. Connect handpiece.
The handpiece heater assembly sensor is open. Refer to the
appropriate handpiece manual
“ Shorted Sensor Error” The handpiece heater assembly sensor
is shorted. Refer to the appropriate handpiece manual.
“Over Circuit Error” The handpiece heater assembly may be
defective. Refer to the appropriate handpiece manual
Contact
PACE or your authorized local representative for assistance.
Power Source
Most malfunctions are simple and easy to correct.
Symptom Probable
Cause
Solution
No power to
system
Blown Fuse
Check handpiece using Heater Assembly Checkout
Procedures in the appropriate handpiece manual.
Replace the fuse (located in the AC Receptacle Fuse
Holder) with one of the same rated value (see Table 4,
Spare Parts)
Defective Heater
Refer to the appropriate handpiece manual
Handpiece will
not heat
Power Source Malfunction
Contact PACE