background image

©2012 PACE Inc., Southern Pines North Carolina                All Rights Reserved 

    Page 8 of 20 

The Tip & Tool Stand can be mounted to the power source.  If the system will be placed on the 
workbench, this is recommended.  If the power supply is to be mounted under the workbench or shelf, 
the Tip & Tool Stand should not be mounted to the power source. 

 

 

To attach the stand to the power source:   

1.  Insert the 2 large hex head Mounting Screws (head first) into the 

lower “T” slot on the side of the power source case as shown.  

2.  Place the Tip & Tool Stand beside the power source.  Insert ends 

of the 2 Mounting Screws into the 2 Tip & Tool Stand mounting 
holes as shown. 

3.  Install a Thumb Nut onto the end of each Mounting Screw and 

tighten Thumb Nuts. 

4.  Place the handpiece into its Tip & Tool Stand. 

 

Handpiece Connection (All Models) 

 

Connect the handpiece connector plug into the Power Receptacle in the 
following manner. 

 

1.  Align guide on connector with slot on power receptacle. 
2.  Insert connector into power receptacle. 
3.   Turn the connector housing clockwise to lock in place. 

 

 
 

 
 

Air Supply Connection (For ST 65 Only)  

 

The ST 65 system utilizes an integral air venturi system to provide air pressure and vacuum for any 
connected PACE handpiece requiring air/vacuum.  Your in-house air supply must be connected to the 
system power source.

 

 
 
 
 

 
 

1.  Connect air supply to the ST 65’s air inlet on the back of the system.   

 

2.  Install the Connector (with Small, Flexible Air Hose) onto the Air 

Hose Fitting (or metric adapter) finger tight. Using an appropriate 
wrench, tighten the Connector an additional 1/4 turn. 

DO NOT 

over 

tighten. 

 

3.  Connect the free end of a the air hose to your air supply using the 

appropriate fittings. 

 
 
 
 
 

NOTE 

IntelliHeat systems are designed for use with PACE handpieces with 

blue power connectors.  Older “black” connector handpieces can be 

used by purchasing the optional adapter (P/N 6993-0278-P1). 

IMPORTANT 

The system must be connected to a clean, dry, and filtered, 
compressed  air supply regulated to 5.48 Bar (80 P.S.I.). 

 

NOTE

The Air Hose Fitting on the rear of the ST 65 requires a 1/8-27 NPT threaded airline fitting (to be supplied by 

customer). 

DO NOT 

over tighten connections. Damage to the system could occur if excessive torque is applied 

to the Air Hose Fitting, Connector, or Metric adapter (G1/8 ISO thread, Part Number 1259-0081).

 

Summary of Contents for IntelliHeat ST 30

Page 1: ...B This manual applies to Model Part Number ST 30 7008 0290 01 ST 30E 7008 0290 02 ST 50 7008 0291 01 ST 50E 7008 0291 02 ST 65 7008 0292 01 ST 65E 7008 0292 02 ST 70 7008 0293 01 ST 70E 7008 0293 02...

Page 2: ...led Power Supplies ST 30 ST 65 ST 75 Operation 10 Temperature Dial Lock 10 Analog Control LED Operation 10 Digital Temperature Controlled Power Supplies ST 50 ST 115 Operation 11 Digital Control LED O...

Page 3: ...ce Requirements Domestic Models Export Models ST 30 ST 30E ST 50 ST 50E ST 65 ST 65E ST 70 ST 70E ST 75 ST 75E ST 115 Operates on 97 127 VAC 50 60Hz 80 Watts maximum at 115 VAC 60Hz ST 115E Operates o...

Page 4: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 4 of 20 Power Supply Features A A B B C D E F C G J I H D E L E K C O P Q R O P Q R S O P Q R ST 30 ST 50 ST 65 FRONT BACK...

Page 5: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 5 of 20 A B B M E N C L E K C D O P Q R ST 115 ST 75 R P T Q O ST 70 F C G J I H E L K R P T Q O...

Page 6: ...menu functions I Digital control LED Indicates status of power supply J Digital display Displays temperature setting and menu functions K Vacuum inlet Vacuum connection for SX 90 TP 65 TP 100 Handpiec...

Page 7: ...ighly recommended to help protect personnel from solder flux fumes 5 Exercise proper precautions when using chemicals e g solder paste Refer to the Material Safety Data Sheet MSDS supplied with each c...

Page 8: ...pply Connection For ST 65 Only The ST 65 system utilizes an integral air venturi system to provide air pressure and vacuum for any connected PACE handpiece requiring air vacuum Your in house air suppl...

Page 9: ...d end of a male quick fit connector P N 1259 0087 into the free end of the 1 inch 2 5cm length of air hose connected to the FLOW OUT side of the VisiFilter 3 Connect the free end of the 137cm 54 inch...

Page 10: ...Temp Locking Ring closest to the front panel Dial Control LED Operation The colored LED on the power source front panel indicates Power Receptacle output status LED Full On Red A fault has occurred Ch...

Page 11: ...offset may be entered if using massive tips To enter an offset simply press the program key while the system is in normal operation mode and enter the offset using the keypad The display will return t...

Page 12: ...life and save energy the ST 50 and ST 115 systems can be programmed to automatically set back its Tip Temperature to 177 C 350 F after a selected period of handpiece inactivity adjustable 10 90 minut...

Page 13: ...nd the system will return to normal operation If this occurs repeat steps 1 2 and enter the correct Password b The LED Display reads P Choose one of the following options i Press the Program Key to ke...

Page 14: ...the following a Press and release the Program Key to keep the currently stored Auto Off time b Adjust the Auto Off value using the keypad c Press and release the Program Key to proceed to the next st...

Page 15: ...the front of the unit 3 The LED indicator will turn amber while the tip is heating to the desired performance level 4 Once the tip has reached the desired heat level the LED indicator will turn green...

Page 16: ...1 Green 5 260 C 500 F 1207 0446 02 P1 Turquoise 5 5 288 C 550 F 1207 0446 03 P1 Orange 6 316 C 600 F 1207 0446 04 P1 Gold 6 5 343 C 650 F 1207 0446 05 P1 Red 7 371 C 700 F 1207 0446 06 P1 Violet 7 5 3...

Page 17: ...ter setscrew on the Variable Temperature Control knob furthest from front panel using the Temp Locking Key hex key supplied with the system c Position the knob with the pointer aligned to match the te...

Page 18: ...he correct password Open Sensor Error No handpiece is connected to the power receptacle Connect handpiece The handpiece heater assembly sensor is open Refer to the appropriate handpiece manual Shorted...

Page 19: ...p Time Lag 1159 0246 P5 1 Fuse 0 5 Amp Time Lag Export Models 1159 0213 P5 2 Silicone tubing For SX 90 TJ 85 Handpiece 1342 0015 08 3 Quick disconnect male fitting 1259 0087 P1 4 Venturi solenoid kit...

Page 20: ...Y OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user or pro...