6. Press and release the Tip Temperature Set
Key. The Digital Readout will display "S-X" (X = 1 -
9). Either the °F or °C will be on. This is the default
readout (e.g., if the °C LED is on the Digital
Readout will display temperature readings in °C).
°F or °C READOUT DEFAULT
7. Press and release the °F/°C Key to change the
default. Each subsequent press and release of the
key will change the default
AUTOMATIC SETBACK
8. As received from the factory, the
temperature will read "S - -" meaning that
Automatic Setback is turned off. A readout of 1
thru 9 on the right side of the Digital
Readout indicates time toAutomatic Setback
in increments of 10 minutes. For example, "S-3"
would indicate a timeout of 30 minutes.
To change the Automatic Setback
feature, press the Scroll Up Key to
increase the timeout and/or enable the feature.
Press the Scroll Down Key to decrease the
timeout.
9. Press the Tip Temperature Set Key to store the
°F/°C default and Automatic Setback value in
system memory. The Digital Readout will revert to
display "CAL" and only the Channel 1 LED will remain
lit