SET-UP
2.
Insert a Male Quick Connect Hose Mount Fitting (attached to
VisiFilter assembly) into the Female AUTO SNAP-VAC Port on
the front panel of the power source.
3.
Attach the ribbed end of a Male Quick Connect Hose Mount
Fitting (P/N 1259-0087) to each end of the 54 inch (137cm)
translucent Air Hose. Push and turn hose onto each Fitting to
seat properly. You may install metal hose clamps (enclosed
with system) to further secure connections.
4.
For each air handpiece, attach ribbed end of a Female Quick
Connect Hose Mount Fitting to a 1 inch (2.5cm) length of clear
pvc Air Hose; push and turn hoses onto Fittings to seat
Air
Hose
Fitting
Figure 11. Air Hose To Handpiece
properly. You may install a metal hose clamp (enclosed with system) to further secure the connection.
5.
Attach the opposite end of the 1 inch (2.5cm) length of clear pvc Air Hose to the metal tube located at
the rear of each handpiece.
6.
Connect one end of the long Air Hose (with attached Male Quick Connect Hose Mount Fitting) to the 1
inch (2.5cm) clear pvc Air Hose attached to the rear of the handpiece.
7.
For vacuum, insert Male Quick Connect Hose Mount Fitting attached to the remaining end of the long
Air Hose into Female Quick Connect Hose Mount Fitting on 1 inch (2.5cm) clear pvc Air Hose
(connected to VisiFilter). For pressure, insert Male Quick Connect Hose Mount Fitting directly into the
Controllable PRESSURE Port.
8.
The long Air Hose may now be easily transferred between air handpieces by removal of Male Quick
Connect Hose Mount Fitting (attached to long Air Hose) from Female Quick Connect Hose Mount
Fitting at rear of air handpiece and attachment to another air handpiece.
CAUTION
When removing any Air Hose, turn and pull. DO NOT attempt to pull Air Hose
directly off. Damage to or breakage of Fitting or VisiFilter may occur.
9.
Connect the handpiece power cable connector plugs of each air handpiece to the Power Output
Receptacles.
23