S Y M P T O M
PROBABLE CAUSE
SOLUTION
Foot Pedal does not activate
vacuum or air pressure for
Thermal Management Center.
Foot Pedal connected to
incorrect receptacle for
Thermal Mgt. Center motor
pump activation.
Connect Foot Pedal to any spare AUX
Power Receptacle on Thermal
Management Center.
Defective motor pump.
Contact PACE Service Department.
Microprocessor pcb defect.
Contact PACE Service Department.
Keys on Thermal
Management Center don't
function properly.
Key caps binding.
Clean and/or adjust Key caps.
Display pcb misaligned or
defective.
Contact PACE Service Department.
Microprocessor pcb
defective.
Contact PACE Service Department.
Cannot adjust Offset or Set
Tip Temperature on Thermal
Management Center. Digital
Readout displays "P--".
System is requesting
Password entry.
Enter Password.
Operator forgot Password.
Clear Password. See "Clearing a
Password" instructions.
Digital Readout on Thermal
Management Center is grossly
inaccurate.
System out of calibration.
Wait 4 minutes for system to perform
automatic internal recalibration.
Shorted handpiece or
accessory connected to
AUX or Power Receptacle.
Disconnect handpieces and
accessories. Repair defective
handpiece or accessory.
Defective Microprocessor
pcb.
Contact PACE Service Department.
Table 7. Corrective Maintenance, Power Source Cont'd
Summary of Contents for PRC 2000
Page 1: ...1 SYSTEM OPERATION MAINTENANCE MANUAL PRC 2000 SYSTEMS ...
Page 2: ...2 ...
Page 3: ...3 MANUAL NO 5050 0313 REV G ...
Page 17: ...17 Figure 6 Thermal Management Center ...
Page 23: ...23 Figure 12 Pik And Paste Section ...
Page 74: ...74 ...
Page 95: ...95 Figure 122 Pulse Plate Set Up ...
Page 96: ...96 ...
Page 102: ...102 ...
Page 111: ...111 ...
Page 119: ...119 ...